Order them separately referring to Mounting Bolt for C(D)Q2B on pages 156 and 157. Large bore Note 8) Air-hydro not available with non-rotating rod (K). Note 7) Note 7) Stroke standard (pneumatic) Long stroke 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 Bore 12 16 20 25 32 40 50 63 80 100 125 140 160 180 200 Note 7) Only CQ2 is available with 180 and 200 bores.
1 V 1.04 V 5 V 4 mA 4.16 mA 20 mA PFMB7501 5 L/min 500 L/min PFMB7102 10 L/min 1000 L/min PFMB7202 20 L/min 2000 L/min PFMB7501(500L/min) PFMB7102(1000L/min) 200 kpa [kpa] [kpa] 200 kpa 400 kpa 400 kpa [L/min] [L/min] PFMB7202(2000L/min) 200 kpa [kpa] 400 kpa [L/min] -65No.PF-OMP0001CN-F IN 3F.S.8 cm IN OUT [cm] -66No.PF-OMP0001CN-F PFMB7501/7102/7202 2x A B D E F H K L N PFMB7501/7102
[F 2] OUT2 38 No.LFE*-OMY0008 c. / Add/dEC OUT1 (31 ) ( [n2AH]) ( [n2dH]) c.(32 ) 4. 4. 4. 4.
(between FE and all accessible terminals) Insulation resistance 10 M or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z Vibration
LAT3LAT3MLAT3F600 350 700 Load weight1000g Load weight1000g Load weight1000g 300 600 Positioning time [ms] Positioning time [ms] Positioning time [ms] [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
[dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.44 0.40 0.40 0.44 0.40 0.41 0.63 0.63 0.41 0.63 0.13 0.10 0.10 0.13 0.10 0.20 0.14 0.14 0.20 0.14 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.47 0.38 0.38 0.47 0.38 0.76 0.41 0.41 0.76 0.41 0.44 0.27 0.27 0.44 0.27 0.26 0.24 0.24 0.26 0.24 0.13 0.10 0.10 0.13 0.10 0.19 0.15 0.15 0.19
V 200 V or less 5 V 3-wire (NPN equiv.)
-2No.PS-OMF0005CN-E / 1 1.5 *3) 1 1 [] -3No.PS-OMF0005CN-E () () -4No.PS-OMF0005CN-E () * 5 m -5No.PS-OMF0005CN-E * (RcNPTG) 1/8 79 Nm 1/4 1214 Nm 1.52 2 * () ()() () () -6No.PS-OMF0005CN-E * IP66IP65 () 060 (5 ) * -7No.PS-OMF0005CN-E (ISA2 ) * * (EXH) 5 m 0.2 MPa CE (2 VCA ) () C-R () ()C-R ( ) () AC 10 DC 2 * * 2 0.51.25 mm -10+10 5 -8No.PS-OMF0005CN-E *
) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 700 800 900 Flow rate (l/min (ANR)) Inlet pressure (MPa) 7 Direct Operated Precision Regulator/Modular Style Series ARP20/30/40 Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e C SM 2 OUT A A IN OUT t A-A BLEED w y Note Component Parts
) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 700 800 900 Flow rate (l/min (ANR)) Inlet pressure (MPa) 7 Direct Operated Precision Regulator/Modular Style Series ARP20/30/40 Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e C SM 2 OUT A A IN OUT t A-A BLEED w y Note Component Parts
[dm3/ (sbar)] C [dm3/ (sbar)] C [dm3/ (sbar)] C [dm3/ (sbar)] V100 Grommet b Cv b Cv b Cv b Cv S070 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.44 0.27 0.27 0.44 0.27 0.26 0.24 0.24 0.26 0.24 0.13 0.10 0.10 0.13 0.10 0.19 0.15 0.15 0.19 0.15 0.47 0.39 0.39 0.47 0.39 0.80 0.55 0.55 0.80 0.55 0.40 0.35 0.35 0.40 0.35 0.27 0.32 0.32 0.27 0.32 0.13 0.10 0.10 0.13 0.10 0.19 0.14
XLH-25 XLH-40 XLH-50 AC90240V XLA25-60S-1 XLA25-60S-1 1 1 H4 AC100V 200/40 200/50 / AC200V 800/40 800/50 XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 1 1 1 H5 AC100V 200/40 400/70 400/80 / AC200V 800/40 1600/80 1600/80 1 216 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 30 ( 7 XL-OMY0003 . <> 1 Ass 'y () ( ) < SUS304> 7 (SUS304) () () 3 < SUS316L> 6 (SUS316L) <
B N.O. 1/2 G 15 With surge voltage suppressor C 110 VAC Stainless steel D 200 VAC 5 20A H C37 N.C. 3/4 20 E 230 VAC C N.O. J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.
C () White Reset (Vacuum suspension) B DC negative common Lead wire colors Set (Vacuum generation) Simultaneous energization protection circuit COM. (+) Red () Black SOL. A C (+) White Reset (Vacuum suspension) B AC type Lead wire colors 100 VAC, 200 VAC Set (Vacuum generation) Yellow Yellow A 3.
Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.
It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below. For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.
LEY25: 200 or less LEY32: 100 or less 3. In case of [Double clevis], use the actuator within the following stroke limit. LEY16: 100 or less LEY25: 200 or less LEY32: 200 or less 4. G Head flange is not available for LEY32. Nil 1 3 5 8 A B C Without cable 1.5 3 5 8 !
B Grommet 100 VAC With surge voltage suppressor 12 One-touch fitting C 110 VAC G H J K 3/8 D 200 VAC 4 10A C37 N.C. 1/2 E 230 VAC 15 15A 3/8 Stainless steel B N.O. F 24 VDC 1/2 G DIN terminal 24 VDC L M 5 20A C37 N.C. With surge voltage suppressor 3/4 20 H 100 VAC C N.O. Stainless steel J 110 VAC 6 25A N.C. N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C.
8 F 24 VDC 5 G DIN terminal 24 VDC With surge voltage suppressor A B D E H J L M 4 H 100 VAC Size 2 2 1/4 N.C. 7 J 110 VAC Aluminum 4 5 N.O. 3/8 K 200 VAC 7 L 230 VAC 4 8 7 Resin (With bracket) M Conduit terminal 24 VDC With surge voltage suppressor 4 N 100 VAC 10 7 P 110 VAC A B C D E F G H J K L M N 5 Q 200 VAC Size 3 3 N.C. 8 1/4 R 230 VAC 10 (N.C. only) 6 N.O.
10 400 12 10, 25, 40, 50, 80, 100, 125, 160, 200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000 25 Refer to pages 101 to 111 for cylinders with auto switches.