ASV T AK ASS Inch Size ASR L4 L5 A1 A2 M1 Max.
Changeable Range 01 Tie Rod Length (mm) Model' CS2 Bore-size 125 ' 140 160 Mounling brack.1 L 1!I, I'i q , C"D, T L I B, F, G, 'C, 0 , T L IB, F, G, C, 0, T ' -Mminimum 20 1 12 21 1 12 23 1 14 M.ro' axirourn . 270 rn 3 o o ~ n '5. ::J C.
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Thermometer Pressure switch Control circuit Solenoid valve Pressure control equipment
Applicable stations 01 Station 1 PW J kit: PC Wiring System compatible Double wiring 16 Station 16 T kit: Terminal block kit Single wiring T kit: Terminal block kit Double wiring TS Note 1) No symbol required for "F0".
T kit of VQ0 and all of VQ1000 are equipped with a DIN rail, so indicate suffix -D. Specify the wiring specifications on the manifold specification sheet. Note 1) 1 station 01 16 stations Note) Number of terminals 16 Note 2) Refer to page 2-4216 for details.
T0425 (0.5 m) H04-01 (1 pc.) DL04-01 (1 pc.)
If Option T is selected, Option T1 cannot be selected.
T1) terminal block) -1A: +COM -1NA: COM SX3000-64-1A 1NA SX5000-64-1A 1NA t-1 SX3000-64-26 2A 2NA SX5000-64-26 2A 2NA t-2 Note) 24 VDC -2A: +COM. -2NA: COM. 2A 2NA SX3000-64-20 2A 2NA SX5000-64-20 t-3 2A 2NA SX3000-64-10 2A 2NA SX5000-64-10 t-4 t-5 SX5000-64-3A SX3000-64-3A In common between +COM and COM.
How to Order VVEXB 5 01 1 Body size Thread type Port size Nil F N T Rc G NPT NPTF Pilot type Internal pilot Common external pilot Valve stations 01 8 1 1 2 2 2 stations 10 10 stations VVEX2 5 02 1 Body size Thread type Port size Nil F N T Rc G NPT NPTF Pilot type 4 1 02 1 2 Internal pilot Common external pilot Valve stations 2 2 stations 8 8 stations List symbols in the order of precision
0 i t !2 q !1 @0 !7 t !2 u !1 !7 !0 t !2 !7 !1 !5 !6 Component Parts Description Note Description No. Material Material Note No.
Connection thread NPT T Applicable tubing O.D.
(Manifold base) SYJ7120-5G-01 . 2 pcs. (Valve) SYJ7000-21-1A .1 pc. (Blank plate ass'y) PSS5YJ7-41-03-01 . 1 pc. (Manifold base) SYJ7140-5LZ .1 pc. (Valve) SYJ7240-5LZ .1 pc. (Valve) SYJ7000-21-1A .1 pc.
4.4 16 T 1 4 KGY04-02 26 38 19 4.3 12 KGY06-M5 KGY06-01 29 14 39 14.5 17.5 23 17.5 4.6 4.6 7 11.5 VMG 1 8 10 6 10 20 12.8 1 4 KGY06-02 27 41 17 17 14 13.4 10.6 20 3 8 KGY06-03 29 42.5 34 1 8 1 4 KGY08-01 KGY08-02 43.5 45.5 24.5 28.5 12 17 13.4 10.6 14 22 12 23 15.2 8 14 25.6 18.5 17.7 3 8 KGY08-03 17 30.5 47 36 1 8 KGY10-01 27 49.5 31 1 4 3 8 KGY10-02 KGY10-03 50.5 52 30 32 17 29
S With sealant (all male threads except M5) C O N N E C T I O N T H R E A D M5 M5 01 1/8 02 1/4 03 3/8 04 1/2 00 Same dia. tube 99 Stem fitting P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R T U B E O.D. 04 4mm 06 6mm 08 8mm 10 10mm 12 12mm KCH S T R A I G H T P L U G KCH F O R F R E Q U E N T U S E Courtesy of Steven Engineering, Inc. !
With One-touch fitting Port size For low speed control M5 U10/32 01 02 M5 x 0.8 10-32 UNF 1/8 1/4 Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT N Needle Valve/Flow Characteristics AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 0.8 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa
T (M) L2 L1 M Nylon Urethane 1 4 13 13 M12 X 1 3.2 KQ2E23-02 3.4 2.9 17 14 14 31.5 15 15.5 1 8 KQ2E04-01 11 5.6 4 16 13 16 27.5 31 M12 X 1 4 14 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 3 8 1 2 3 8 1 2 15 35 KQ2E04-02 17 KQ2E06-01 11 28 31.5 30 15 17 M14 X 1 19 KQ2E06-03 17 33.5 29 KQ2E06-02 15 6 13.1 10.4 17 17 17 KQ2E08-01 7.5 27.5 28 26.1 18.0 8 18.5 19 KQ2E08-02 13 33 27 17 M16 X 1 19 KQ2E08
Type 40 (5 Port/Base mounted) How to Order SS5YJ740 05 01 P port 1/4 Thread type Stations 01 1/8 A, B port size Nil F N T Rc G NPT NPTF 02 2 stations : : R port 1/4 20 20 stations Applicable solenoid valve SYJ740SYJ743A, B port Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.