(Note 4)The F .S. means the condition at the maximum setting pressure of the product. (F .S. 0.8MPa, IR2120) (Note 5) Repeatability: This is the reproducibility of the downstream pressure at every operation (ON/OFF) on the downstream side.
C (dm 0.6 [1 (P) 2 (A) ] 0.5 [2 (A) 3 (R) ] bar) ) b 0.2 [1 (P) 2 (A) ] 0.15 [2 (A) 3 (R) ] Rc, NPT, G1/8 ON Delay 480g (*) 4 4 V R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec B (3) (MPa) 3 OFF 1)4 1) OUT 0.7 0.6 VM1 VM1 () 0.5 0.4 0.3 0.2 ,0.6MPa VM2 VM2
Option: Pressure gauge G15-10-01 How to Order NARM2000-4A2-N01G G15 P10 01 Symbol Units Nil MPa P PSI Common IN Individual IN IN M5 x 0.8 .39 (10) Max. pressure indication 10 150PSI (1.0MPa) .59 (15) IN OUT OUT *Pressure gauge for 30psig (0.2MPa) is not available.
Note 3) The handle of the selector (2 position) cannot be removed or replaced alone. 5-6-35 Series VZM400 How to Order S 01 01 0 VZM45 Option Suffix for actuator F Foot bracket (Only internal pilot) Actuator type R S G B Red Hard steel roller Port size Basic 00 Color of push botton selector Rc 01 1 8 NPT N01 1 8 G F01 1 8 Roller lever 01 Black One Way Roller Lever 02 Green Straight plunger
With barb fitting With nut fitting With one-touch fitting Socket/Plug Symbol P S Type Plug Socket Semi-standard Socket (With sleeve lock mechanism) L Port size variations Barb fitting type Nut fitting type One-touch fitting type Male/Female thread type Symbol 06 08 10 12 07 09 11 13 Thread size R, Rc1/8 R, Rc1/4 R, Rc3/8 R, Rc1/2 NPT1/8 NPT1/4 NPT3/8 NPT1/2 Hose nominal 6 (1/4") 8 (1/4")
(-) 1 s Display to show the pressure range Thank you for purchasing the SMC ZSE40A(F)/ISE40A Series Digital Pressure Switch.
(50 ms, 0.5 s, 2 s are selectable) Output protection Short circuit protection Output mode Hysteresis mode, window comparator mode, Accumulated output mode, Accumulated pulse output mode Hysteresis Variable Response time 1.5 s Voltage output Output voltage: 1 to 5 V Output impedance: 1 k Analogue output Output current: 4 to 20 mA Current output Max. load impedance: 600 (24 VDC) Min. load
Specifications Fluid Compressed air Supply pressure 0 to 1.0 MPa Input signal pressure 0.25 to 0.8 MPa Delayed time 0.5 to 60 s Repeated accuracy * +/10% F.S.
(The SI unit type is provided for use in Japan.) + Voltage AC/DC 48 V 100 V Nil S None With seal w w Seal Max. operating current and range 50 mA 40 mA 20 mA Note 2) + Nil 6 Note1) Set pressure range 0.1 to 0.4 MPa 0.1 to 0.6 MPa a Semi-standard + Nil L Z 0.5 m 3 m 5 m Lead wire length q e b Series IS10 + Nil P Note2) Scale plate pressure unit MPa Both MPa and psi c CAT.ES60-19A Series IS10
Model no. of NPT thread is AN101N01 and AN110-N01. Note 2) It indicates the inlet pressure for solenoid valve. Note 3) It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing. VEX Refer to page 5-10-13 for Precautions on these products.
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)
(The SI unit type is provided for use in Japan.) + Voltage AC/DC 48 V 100 V Nil S None With seal w w Seal 50 mA 40 mA 20 mA Max. operating current and range Note 2) + Nil 6 Note1) Set pressure range 0.1 to 0.4 MPa 0.1 to 0.6 MPa a Semi-standard + Nil L Z 0.5 m 3 m 5 m Lead wire length q e b Series IS10 + Scale plate pressure unit MPa Both MPa and psi Nil P Note2) c CAT.ES60-19A
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)