SMC Corporation of America
Elite Part Number Search
Search Results "ZCDUKC10-20D-M9N"

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 5mm

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 15mm

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 10mm

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Bore Size: 20mm, Finger Position: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M

Bore Size: 20mm, Finger Position: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M

Magnet: D (Built-in Magnet), Mounting: L (Foot), Bore Size: 16mm, Stroke: 20mm, Rod End Thread: w/Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M

Clean Series: 10 (Relief Type), Magnet: D (Built-in), Bore Size: 16mm, Stroke: 20mm, Rod End Thread: Female, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Clean Series: 10 (Relief Type), Magnet: D (Built-in), Bore Size: 10mm, Stroke: 20mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Clean Series: 11 (Vacuum Suction Type), Magnet: D (Built-in), Bore Size: 10mm, Stroke: 20mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Clean Series: 22 [Vacuum Suction Type (Copper, Fluorine and Silicon-free + Low Particle Generation)], Magnet: D (Built-in), Bore Size: 10mm, Stroke: 20mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal