Rc G NPT Nil F N Port size 04 1/2 (Female thread) 14-20-51 2 Series ADH4000 Construction Component Parts q o i u !1 No.
The length of wiring to the load is 5m or more. 3. The load voltage is 100 or 200VAC. 0.5m 3m 5m Nil L Z Use a contact protection box in any of the above situations. The life of the contacts may otherwise be reduced. (They may stay ON all the time.)
LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C Power Connector Cable LC6D Connector Cable Model LC6-1-C1--X258 Model LC6-1-C2--X252 Electric actuator LC6D Electric actuator LC6C Cable length 1 1m 3 3m 5 5m Cable length 1 1m 2 2m 5 5m Power connector Cable length: 1 to 5m Motor cable b Cable length: 1 to 5m 13 12 11 10 6 5 4 3 2 1 a Motor cable 7 13 12 11 10 9 8 6 5 4 3 2 1 Switch cable 14 15 16 17
Handling Caution q All loads to piston rod must be applied in axial direction only. Unavoidable side loads to rod end must be less than the values in the graphs. Cylinder installation requires accurate alignment.
Tubing size (O.D. x I.D.) mm: 12 x 9 0m (0ft) 20C (-4F) 1m (3.3ft) 19 C (-2.2F) 3m (9.8ft) 17 C (1.4F) 5m (16ft) 16 C (3.2F) Note) In case of models other than the above, the outlet air atmospheric pressure dew point will increase by 1C (34F) or less for tubing lengths of 5m (16ft) or less. 3 4 Series IDG Membrane Air Dryer Single Style/Standard Dew Point 15C (5F) Specifications How to Order
3 y e q w !7 r !4 !8 !6 !2 t u !5 o !1 !
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area [mm] P: Pressure drop rate (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
D-Across Flats CD F CW CW CB 2-EE (NPTF) Q Width Across Flats KK C KK AA Bore 200 250 325 400 Q 3/4 3/4 1 1/16 1 1/16 MM B B EA LR A C DD FA G A J R LF + Stroke E L M ZB + Stroke XD + Stroke X119US Option (in) C Bore (in) AA Y A E LF XD WF B EA D CD P EE F CW MM ZB J M LR KK CB DD G L FA R 1/2 200 (2") 2.6 2.09 1 1/8 2 1/2 3 5/8 5 3/4 1 3/8 1 1/2 0.3 7/8 1/2 2.40 3/8 3/8 1/2 1 5 1/8 1.06
Therefore, perform a warm up operation of the cylinder. q t w q 1.15-34 Balance Controller Series VY511/VYU5 Valves AC 3 position valve (VEX3222-5M) Electro-pneumatic HYREG (VY1200-00-N) AV Caution Caution Pressure gauge If equipped with a pressure gauge, be aware of the possibility of the gauge being affected due to sudden pressure fluctuations.
o q Plug y Purge air for dehumidification u Plug u Purge r Purge Purge air for dehumidification Component Parts Material Description No.
Formula (2) Effective inside diameter of piping Fluid flow velocity (m/s) Fluid volume (l/min) Effective inside diameter of piping (mm) V: Q: din: Fluid flow velocity Formula (3) din x 10__ 4 V = Q 1 ___ 60 Rubber hose 5m/s Steel piping 4.5m/s 600 General range of rubber hose (max. 5m/s) Cylinder bore size 160 500 General range of steel pipe (max. 4.5m/s) 11/2"(38.1) Rubber hose 400 Cylinder
L Y69BL 5m . Z Y69BZ Note 2) Solid state auto switches marked with a "" are produced upon receipt of order.
L Y69BL 5m . Z Y69BZ Note 2) Solid state auto switches marked with a "" are produced upon receipt of order.
1 A Q a q 0 0 1 0 2 STX DC2 2 B R b r 0 0 1 1 3 ETX DC3 # 3 C S c s 0 1 0 0 4 $ 4 D T d t 0 1 0 1 5 5 E U e u 0 1 1 0 6 & 6 F V f v 0 1 1 1 7 7 G W g w 1 0 0 0 8 ( 8 H X h x 1 0 0 1 9 ) 9 I Y i y 1 0 1 0 10 : J Z j z 1 0 1 1 11 ; K [ k { 1 1 0 0 12 , L l | 1 1 0 1 13 M ] m } 1 1 1 0 14 . N ^ n 1 1 1 1 15 / ?