Stations: 1 Station, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 06D (3/4, Bottom), PR Thread: T (NPTF), Silencer: SB (Silencer Box)
Stations: 8 Stations, AB Port: 04Y (1/2, Bottom), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom)
Stations: 6 Stations, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 06D (3/4, Bottom), PR Thread: T (NPTF), Silencer: SB (Silencer Box)
Stations: 6 Stations, AB Port: 04R (1/2, Right), Thread: T (NPTF), Control: None, PR Port: 06D (3/4, Bottom), PR Thread: T (NPTF)
Stations: 9 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom)
Stations: 2 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 3 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 4 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 5 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 7 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 8 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 2 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: E (w/Air Release Valve), PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: None, Voltage: 3 (24VDC)
Stations: 3 Stations, AB Port: 04Y (1/2, Bottom), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 1 Station, AB Port: 04Y (1/2, Bottom), Thread: Rc, Control: None, PR Port: 06D (3/4, Bottom), PR Thread: Rc, Silencer: SB (Silencer Box)
Product part number Auto drain number Normally closed Normally open HAW2-04C/D AD402-04C-6-A AD402-04D-6-A HAW7-06D AD402-04D-6-A HAW22/37-14D AD600-06 HAW55/75-20D AD600-06 HAW110-30D AD600-10 2) The drain piping, if conducted, should have an inside diameter of at least 10mm and a maximum length of 5m.
Controller Adjustable by Flat Head Screwdriver With One-touch Fitting Dimensions Metric size L2 L3 Applicable tubing O.D. d D1 M1 L6 D2 L1 D4 L4 AS H ASP (Hexagon width across flats) ASN D3 AQ D4 ASV A1 L5 AK A2 L6 ASS ASR ASF T Metric Size A1 A2 L4 L5 L6 D2 L3 D3 D4 Model H L1 D1 L2 d T M1 ASD230F-M5-04D 17.5 9.3 29.4 4 12.9 30.7 31 0.7 9.6 10 4.7 8 11.7 M5 x 0.8 27.4 7.8 ASD230F-M5-06D
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAN. ASSY ISO2 2-STA, VALVE, VV7* MANIFOLD ISO SERIES, SL, VV7* BASE MT 3/4, 5.91800 lb
] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input of the Set point 2 (OUT1) [F_1] Input the Set value of instantaneous output PF2W30 series Selection of the connected sensor [04L
OFF 50% of max. rated flow [n_1] Input of the Set point 1 [F_1] Input the Set value of instantaneous output Selection of the connected sensor Instantaneous output mode Window comparator mode PF2W2 series [04L] 0.5 to 4 L/min type (PF2W504) (PF3W504) P_1 P_2 Instantaneous flow Item Description 50% of max. rated flow [n_2] Input of the Set point 2 PF2D2 series [04d] 0.4 to 4 L/min type (PF2D504
(mm) Part No. 0.1 KQH, KQ2H04-M5, M6 KQS, KQ2S04-M5, M6 KQL, KQ2L04-M5, M6 KQT, KQ2T04-M5, M6 KQY, KQ2Y04-M5, M6 4 KQ2C-04l 2.9 10.1 5.2 4 KQ2C-04A-l 8.5 5 2.2 0.1 2.2 4 KQ2C-04B-l 9.7 5 0.1 Kl 0.1 6 KQ2C-06l 2.9 12.1 7.2 KQH, KQ2H06-M5, M6 KQS, KQ2S06-M5, M6 KQL, KQ2L06-M5, M6 KQT, KQ2T06-M5, M6 KQY, KQ2Y06-M5, M6 Ml 2.2 6 KQ2C-06A-l 10.5 7 0.1 Hl 2.2 6 KQ2C-06B-l 12.0 7 0.1 8 KQ2C-08l 14.1