mode: Variable (can be set from 0), Window comparator mode Note 6): 3-digit fixed 12 to 24 VDC 10% Enclosure Operating temperature range Withstand voltage Insulation resistance Noise resistance IP65 Environment 0 to 50C 1000 VAC for 1 minute between terminals and housing 50 M or more (500 VDC measured via megohmmeter) between terminals and housing 1000 Vp-p, Pulse width 1 s, Rise time 1 ns
LED check Refer to fault EtherNet/IPTM device NS No. 1 LED is ON or flashes () Yes No EtherNet/IPTM device NS Refer to fault Scan is not No. 2 LED is OFF available Refer to fault IP address is not No. 3 held Green ON, Green flashes, Red ON, or Red flashes. -13No.EX-OMV1026-B Troubleshooting list Fault No.1 Problem Possible cause Investigation method Countermeasures Set the IP address switch
resistance Impact resistance Noise resistance IP65 0 to 50C Resistance 1000 VAC for 1 min. between external terminal and case 50M or more (500 VDC Mega) between external terminal and case 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller. 490 m/s2 in X, Y, Z directions 3 times each 1000 Vp-p, Pulse width 1 s, Rise time 1 ns
(de-energized) 490 m/s2 in X, Y, Z directions 3 times each 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Status LEDs Response time Hysteresis Power supply voltage Enclosure Operating temperature range Withstand voltage Insulation resistance Vibration resistance Impact resistance Noise resistance Note 1) For digital flow switch with unit switching function.
The SF/MS/ST and BF/NS/DIAG/SA LEDs of each device will flash red. Connect to the webserver. The available remote devices will appear in the "FREE REMOTE" section. Using the symbol, click and drag the remote devices up to the "SYSTEM CONFIGURATION" section.
I n t he com m uni cat i on cabl e( 5 pi ns) i s connect ed t o t he connect or f or t he pow er suppl y cabl e( 4 pi ns) by m i st ake, t he i nt ernal subst rat e can break. Pay at t ent i on f or connect i ng t he cabl e. The ri ght angl e cabl e connect or does not rot at e. D o not rot at e i t .
2 i MS, NS Communication status LED Displays the status of the EtherNet/IPTM communication t o ENC z Encoder connector (16 pins) Axis 1: Connect the actuator cable. !0 MOT z Motor power connector (6 pins) !8 @1 !1 ENC x Encoder connector (16 pins) Axis 2: Connect the actuator cable. !2 MOT x Motor power connector (6 pins) !9 @0 !3 !4 y !
Wireless communication connection status PB72, 02231, Espoo, Finland W-NS Restorable error is detected. (LED flashes when more than one diagnostic information item is detected.)
of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX D-X 20Data (mm) Stroke (mm) 5 10 15 20 25 30 TS Z S NS LS BS 52.5 53 41.5 14 14 10 57.5 58 46.5 14 19 14 62.5 63 51.5 24 25 18 67.5 68 56.5 24 30 24 75.5 76 64.5 34 40 32 79.5 80 68.5 34 45 35 8-3-7 8 Series MXU Dimensions
-:U'7 9 '7 h '7 t :-'e-ns.--~ t'\ 2Mounting hOleS\ manual overrIde uL.--, . .JoU D~~ 0.22(5.6) Dia :1--;: _ . -r---r r-' !I -,zr n r y'~[ ~ ~I~@ ~ u Ll L4JE ItAII co ... ,,!
St a nd a rd Spe cifi ca t io ns Fluid V9L9P",3!t9 lMin. operating pressurellq ?sr_(9q9q!
MM NC 7.5Depth4.5 9Depth5.5 10.5Depth6.5 13.5Depth8.5 17Depth10.5 NS 43 45 44 54 53 Model MUB25 MUB32 MUB40 MUB50 MUB63 KA 10 12 14 18 18 N 14 15.5 16 21.5 21.5 ND M5 X 0.8 M6 X 1 M8 X 1.25 M10 X 1.5 NE 4.3 5.1 6.9 8.7 10.5 S 55 58 60 74 75 ZZ 69 72 75 92 96 M10 X 1.25 M8 X 1.25Depth13 M12 X 1.25 M14 X 1.5 M18 X 1.5 M18 X 1.5 M8 X 1.25Depth13 M10 X 1.5Depth15 M10 X 1.5Depth15 M12 X 1.75 2.4
34 45 35 8-3-7 8 Series MXU Dimensions: MXU16 (mm) Stroke (mm) 5 10 15 20 25 30 TS Z S NS LS BS 65.5 66 52 24 24 20 65.5 66 52 24 24 20 75.5 76 62 34 35 30 75.5 76 62 34 35 30 85.5 86 72 40 45 40 90.5 91 77 40 50 45 8-3-8 9 Compact Slide Series MXU Construction MXU6 (6) MXU10 (10) MX MTS MY CY MG CX MXU16 (16) D-X With auto switch 20Data Component Parts No. q Note Hard anodized No. !
M12, 5 pins, plug) Power supply connector (M12, 5 pins, plug, reverse key) Power supply connector (M12, 5 pins, plug, reverse key) BUS BUS 59.8 59.8 59.8 PWR PWR PWR Ground terminal 63 Ground terminal Ground terminal 63 63 EX250-SCA1A (CANopen) EX250-SEN1 (EtherNet/IP) EX250-SCN1 (ControlNet) Position indicator LED Position indicator LED Position indicator LED SI UNIT PWR CAN PWR(V) PWR NS
humidity range Storage temperature range Storage humidity range Withstand voltage Insulation resistance Noise resistance 35 to 85%RH (No condensation) 10 to 60C (No condensation and freezing) 35 to 85%RH (No condensation) Between all of external terminals and the case: 500 VAC for 1 minute Between all of external terminals and the case: 50 M(500 VDC) 1000 Vp-p Pulse width 1 s, Rise time 1 ns
MS status Description NS status Installation Green On Green On On-line state, The device has connections in the established state.
(de-energized) 980 m/s2 in X, Y, Z directions 3 times each (de-energized) 500 Vp-p, Pulse width 1 s, Rise time 1 ns Connection Material Weight Power supply / Output connection: 8P connector, Sensor connection: 4P connector (e-con) Housing: PBT, Display: PET, Backside rubber: CR 60 g (Except for any accessories that are shipped together.
St a nd a rd Spe cifi ca t io ns Fluid V9L9P",3!t9 lMin. operating pressurellq ?sr_(9q9q!
No wireless slaves connected (Non-restorable error in wireless communication) 4 W-NS Red/Green Wireless communication connection is under construction. (Pairing) Orange LED is ON.
Stations: 5 Stations, Port Size: C6 (ΓΈ6 One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 5 (Input Block 5 pcs.), Input Block: 2 (M12, 4 Inputs), Input Block COM: N [NPN (-)], Option 1: N (Name Plate), Option 2: S (Built-in Silencer, Direct Exhaust)