Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
How to Order Sub-plates 04 P VQ5000 Electrical entry Port size Replacement of pilot valve assembly (Voltage) Refer to pages 2-6-40 to 2-6-41 for pilot valve assembly part numbers. Refer to page 2-6-3 for replacement method. 04 Rc 1/2 Porting specifications P S Plug-in conduit terminal Plug lead Note1) For bottom ported, port size is Rc 1/2.
5/16" (Station 1) (Station n) (External pilot type) (56.5) 11.8 (For DIN rail mounting) 59.5 56.6 P 1 P 1 B 45.5 2 2 B 2 B 2 B 2 B (43) 24.6 E E 23 A 4 A 4 A 4 A 4 A 4 8.6 10 7.5 18.3 (Pitch) P = 10.5 One-touch fitting [4(A), 2(B) port] 13.5 18.3 Applicable tubing O.D.: 3.2, 1/8" 4, 5/32" 6, 1/4" L2 = L1 10.5 L3 = 10.5 x n1 + 53 L4 = L3 + 97.5 + 47 x n2 L5 = (L1 L4)/2 L6 = 10.5 x n1 + 42
-03 04 AS420-03 AN30-03 12 x 1 m D AS420-04 AN40-04 SGP15A x 1 m 1723 3 Port 3 Position Valve Body Ported VEX3 Series How to Order Air operated Pilot solenoid VEX3 B 12 0 01 1 Air operated VEX3 D B 5 1 12 2 01 Pilot solenoid Operation type Option 1 External pilot solenoid 2 Internal pilot solenoid Nil None Thread type Nil Rc F G N NPT T NPTF Body size Port size B Bracket (VEX312 only) Body
10 10 5.5 5.5 6.6 6.6 25 30 35 40 3.2 3.2 4.5 4.5 35.8 39.8 49.4 58.4 42 42 48 56 16 20 22 30 28 28 28 30 43.4 48 59.4 71.4 Clevis pin and snap ring are attached.
CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 13 15 17 21 3.2 3.2 4.5 4.5 21.2 21.3 25.6 26.3 47.8 54.8 57.4 65.4 42 42 48 56 26 28 28 36 28 28 28 30 50 57 61.4 71.4 CG-020-24A CG-025-24A CG-032-24A CG-040-24A 20 25 32 40 13 15 17 21 3.2 3.2 4.5 4.5 18.1 20.7 23.6 27.3 35.8 39.8 49.4 58.4 42 42 48 56 16 20 22 30 28 28 28 30 38.3 42.1 53.8 64.6 Rod End Nut Clevis Pin Knuckle Pin
Note Symbol 1P Common Common 3R Common Individual 1 Type 41 Type 42 VHS 3 VV3PA3-42-053-02 Stations 02 2 stations ... ... 20 20 stations To order valves and blank plate assembly mounted onto the manifold, list valves and blanking plate assembly with manifold base part number.
This is a legacy product, and replaced byVV3K3-42-02-01T, MANIFOLD, 2-STA, 3 PORT SOLENOID VALVE, I90, 77.00000 lb
Piping: 42 (Base Mounted), Stations: 7 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 11 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 13 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 15 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 17 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 18 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 19 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 2 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 3 Stations, A, B Port: 01T (NPTF1/8)
Piping: 42 (Base Mounted), Stations: 4 Stations, A, B Port: 01T (NPTF1/8)