・The new “Y□00T-D” spacer with brackets can also be used for connecting AW series regulators from 2 generations before.
or less 0.1MPa 0.15MPa Single 3.2 (0.18) SQ1230 15 or less 80 Metal seal 0.18MPa 0.18MPa Double (latching) Double (latching) Minimum operating pressure 4.5 (0.25) SQ1231 20 or less 80 Rubber seal 0.1MPa 0.1MPa Double (double solenoid) 3.2 (0.18) SQ1230D 10 or less 95 Metal seal 13 or less 0.1MPa 0.2MPa Double 3 position (double solenoid) 4.5 (0.25) SQ1231D 15 or less 95 Rubber seal 20
VN5-A3CA VN5-A3CB VN6-A3CA VN6-A3CB VN7-A3CA VN7-A3CB VN3-A3CA VN3-A3CB VN4-A3CA VN4-A3CB VN4-12CA VN4-12CB NBR VN1-A3CA VN1-A3CB VN2-A3CA Plate ass'y Valve material e FKM NBR VN2-A3CB VN2-12CA VN2-12CB Valve material t Valve cover AS568-010 AS568-011 AS568-012 (32A to 50A are O-ring.) i Pilot solenoid valve SF4--23 FKM VO301-00T-X302 (Refer to page 17-4-29 for part no.)
SY5000222-1A [for 10 valves (20 pcs.)] SY7000221-1A [for 10 valves (30 pcs.)] SY3000222-1A [for 10 valves (20 pcs.)] SY5000221-1A [for 10 valves (20 pcs.)] SY300023-24A [for 10 valves (20 pcs.)]
20 00N 20 stations NPT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SS5X3-20-05 (5 stations) NPTF 00T Stations3 2 1 Connector assembly for L and M types Refer to page 1-6-8.
20 00N 20 stations NPT SS5X3-20-05 (5 stations) NPTF 00T Stations3 2 1 Connector assembly for L and M types Refer to page 1-6-8.
20 00N 20 stations NPT SS5X3-20-05 (5 stations) NPTF 00T Stations3 2 1 Connector assembly for L and M types Refer to page 1-6-8.
Without light AXT100-20-1 With Indicator Light DIN Rail Removal/Mounting Rated voltage 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC Voltage symbol 24V 12V 100V 200V 110V 220V Part no. AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Circuit with indicator light Removing 1. Loosen the clamp screw on the (A) side of both ends of the manifold. 2.
Manifold type CE-compliant Stations P, R port thread type 20 21 Type 20 Type 21 -+ -+ -+ -+ -+ -+ -+ -+ Nil Rc G NPT NPTF 2 stations : 20 stations Nil 02 : 20 R P 00F 00N 00T R P Q CE-compliant P port 1/4 R port 1/4 P port 1/8 R port 1/8 Note) If there are more than 6 stations for type 20, or more than 9 stations for type 21, supply air to both sides of P port and exhaust air from both sides
2 stations 20 stations Note 1) Order DIN rail separately.
(5 Port / Body ported type) Applicable solenoid valve: SYJ3 20-M3 SYJ3 23-M3 SS5YJ3--20-05 AB Port M3 0.5 Applicable blank plate ass'y: SYJ3000-21-1A Valve stations 02 2 stations : : P Port M5 0.8 R Port M5 0.8 20 20 stations Type 31(4 Port / Base mounted type) Type 31 Type S31( ) Single solenoid coil is located on same side as the A, B port.
Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve M5 C4 C6 M5 C4 C6 SS5YJ520 05 SYJ520-A, B port M5 x 0.8 SYJ523-Applicable blanking plate assembly SYJ5000-21-1A Applicable individual EXH spacer assembly SYJ5000-17-1A P, R port thread type Number of stations -+ -+ P port 1/8 02 2 stations R R P Nil 00F 00N 00T Rc G NPT NPTF : : 20 20 stations R port 1/8 Type 40 (5 Port/
Applicable blanking plate assembly SYJ7000-21-1A Type 21 (5 Port/Body ported) How to Order SS5YJ721 05 A, B port P, R port thread type Applicable individual EXH spacer assembly SYJ7000-17-1A Stations 02 2 stations + + Nil 00F 00N 00T Rc G NPT NPTF : : P port 1/4 R P R 20 20 stations R port 1/4 Note) For more than stations, supply air to both sides of P port and exhaust air from both sides
20 00N 20 stations NPT SS5X3-20-05 (5 stations) NPTF 00T Stations3 2 1 Connector assembly for L and M types Refer to page 1-6-8.
(5/32) N7T (1/4) M5 (M5 thread) 2 stations: 68 Addition per 1 station: 20 1/8 NPTF Top VQZ2 2 VQZ200 2 to 20 stations VV3QZ22N7T (1/4) N9T 5/16) N11T (3/8) 1/4 NPTF 2 stations: 114 Addtion per 1 station: 37 1/4 NPTF Top VQZ3 2 VQZ300 2 to 20 stations VV3QZ32How to Order / Manifold Assembly (Example) D side U side 1 3 4 5 Stations 2 VQZ212-5M-N7T 4 pcs.
A port 1/8 SS3YJ7-20 -05 -A port 1/8 P, R port thread type Manifold type Stations Nil Rc G NPT NPTF -+ -+ -+ -+ 20 21 Type 20 Type 21 2 stations : 20 stations 02 : 20 00F 00N 00T -+ -+ -+ -+ R P R P P port 1/4 R port 1/4 P port 1/8 R port 1/8 Note) If there are more than 6 stations for type 20, or more than 9 stations for 21 type, supply air to both sides of P port and exhaust air from both
VQD 24V 12V 100V 200V 110V 220V 24V DC 12V DC 100V AC 200V AC 110V AC 220V AC AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 To remove manifold from DIN rail: 1) Loosen the clamp screw on the A side of both ends of the manifold. 2) Lift the A side of the manifold off the DIN rail and slide it in the direction of the B side.
---M5 SYJ522M---M5 A port M5 x 0.8 Type 20 SS3YJ5--20-05 -Stations Bracket P, R port thread type + + + + Nil Nil 02 : 20 Rc G NPT NPTF 2 stations : 20 stations Without bracket Applicable blanking plate assembly SYJ500-10-1A R P 00F 00N 00T With bracket F P port 1/8 R port 1/8 Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
The proper tightening torque for screws 0.3 to 0.4 Nm Rated voltage With indicator light VZ Voltage symbol Part no. 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 VS (b) VFN Valve Mounting Circuit with Indicator Light After confirming the gasket is correctly placed under the