<br>Couplers that can be used with low vacuum <br>・KK/KKH Series<br>KK2: -100 kPa to 1 MPa<br>KK3: -90 kPa to 1 MPa<br>・KKH Series<br>KKH3: -90 kPa to 1 MPa <br>・KA Series<br>KKA3: -100 kPa to 1 MPa
<br>For more information, refer to the VX2 series catalog, which can be found here. <br> <br>
<br>Max. operating temperature of the TL/TIL, TLM/TILM, and TD/TID series (fixed use) <br>Air/inert gases: 260°C<br>Water: 100°C <br>Max. operating temperature of the TH/TIH series (fixed use) <br>Air/inert gases: 200°C <br>Water: 100°C<br>
<br><br>
<br><br>
<br>Formula: (0.3 + 0.1) x 5 = (0 + 0.1) x V <br>V (volume before change) = (0.3 + 0.1) x 5 ÷ 0.1 = 20 L (ANR)<br><br>
Note) Enter "-BR" for both specifications. Nil B R None 16 16 stations Back pressure check valve Note) No symbol required for "F0". External pilot specification Note) Enter "-BR" for both specifications. 53 Series SQ1000/2000 3. Connection method (Refer to page 52 regarding the procedures for adding stations to a manifold block.)
Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Type, Manual), Bracket: B (w/Bracket)
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Type, Manual), Bracket: B (w/Bracket)
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Type, Manual), Bracket: w/o Bracket, Flow Direction: R (Right to Left)
Series: VP500, Pressure Specification: Standard (0.7 MPa), Voltage: 24 VDC, Electrical Entry: DIN Terminal w/Connector, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Manual, Bracket: w/Bracket, Flow Direction: -
Series: VP700, Pressure Specification: Standard (0.7 MPa), Voltage: 24 VDC, Electrical Entry: DIN Terminal w/Connector, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Manual, Bracket: w/Bracket, Flow Direction: -
Series: VP700, Pressure Specification: Standard (0.7 MPa), Voltage: 24 VDC, Electrical Entry: DIN Terminal w/Connector, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Manual, Bracket: w/o Bracket, Flow Direction: Right to Left
Series: VP700, Pressure Specifications: Standard, 0.7 MPa, Rated Voltage: 24 VDC, Electrical Entry: with Connector, with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Manual, Flow Direction: Left to Right, Soft Start-up Function: with Soft Start-up Function
Series: 7 (VP700), Pressure Specifications: Standard, 0.7 MPa, Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (with Connector, with Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Type, Manual), Flow Direction: Left to Right, Soft Start-up Function: S (with Soft Start-up Function)
10.3 (0.57) PA/B 5.2 (0.29) A/BR 3.8 (0.21) PA/B 8.1 (0.45) A/BR 8.5 (0.47) PA/B 9.2 (0.51) A/BR 9.5 (0.53) PA/B 18 (1.0) A/BP 18 (1.0) PA/B 17.6 (0.98) A/BP 14.4 (0.8) PA/B 18 (1.0) A/BP 17.1 (0.95) PA/B 3.6 (0.2) A/BR 3.24 (0.18) Rc(PT)1/8: Rc(PT) 1/4: M5: PA/B 3.42 (0.19) A/BR 3.24 (0.18) PA/B 3.6 (0.2) A/BR 3.6 (0.2) C4: C8 : C4: Valve effective area mm2 (Cv factor) Note 2) C6: C10
<br>EX126: IP67 enclosure<br>EX250: I/O compatible (sensors and external devices can be connected), IP67 enclosure<br>EX260: Compact, Space saving, Transition wiring between manifolds is possible, IP67 enclosure (The D-sub is IP40)<br>EX500: Gateway unit, IP67 enclosure<br>EX600: Fieldbus communication allows for increased expansion, I/O compatible, IP67 enclosure<br><br>For further details
<br>For the VV5QC11: VVQ1000-80A-1 (12 pcs. per set) <br>For the VV5QC21: VVQ2000-80A-1 (12 pcs. per set) <br>For the VV5QC41: VVQ4000-80A-1 (10 pcs. per set) <br>For the VV5QC51: VVQ5000-80A-1 (10 pcs. per set)