A B A 4 B 2 1 SMC A B D side Stations PE P 1 12 X 2n x 1/4" 4(A), 2(B) port Other dimensions are the same as the side ported type.
Class Size combination Applicable tubing size (mm) 4 x 3 3 x 2 6 x 4 4 x 3 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 12 x 10 10 x 8 19 x 16 12 x 10 19 x 16 12 x 10 25 x 22 19 x 16 25 x 22 19 x 16 Connection threads Symbol 1 2 2 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 Connection threads A A B C D E F A B C D A B C D A B C D A B C D Applicable tubing size (inch) No.
U D U D 179 106 46.8 59.2 83.5 U side Station number 55.5 M5 ground screw 9 9 Electrical entry on U side (LU) 19 34.5 n 12 X 2n-Rc 3/8, 1/2 4(A), 2(B) port B 2 A 4 Indicator light 6 B 2 A 4 A B 5 SMC SMC SMC SMC SMC Cable length A B B B B B Manual override B 2 A 4 A B 4 A B 2 A 4 L2 L1 58.5 P = 41 A B 3 A B 2 A 4 A B 2 A 34.5 48 68.5 P = 41 B 2 A 4 A 1 A X 12 Stations R4.5 15.5 Electrical
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7V D-F7WV D-F7BAVL Approx.
U D side D B Special specification M U side 2 to 10 stations 15 15 Includes number of blanking plate assembly .
D-side w How to order applicable valves VQC 4 0 5 E B 0 Y 1 Series VQC4000 F E D A C B Stations are numbered in ascending order from the D-side.
hole) B C D E F G H Model A 3 8 Rc3 8 Rc3 8 Rc3 8 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL-03-04-04 Rc 133 52.45 42 19 3.5 19 20.95 20.95 133 52.45 42 19 3.5 19 151.1 60.95 47.7 19 3.5 24 26.75 151.1 60.95 47.7 19 3.5 24 26.75 I J K L M N O Model 3 8 Rc3 8 Rc3 8 Rc1 2 Rc1 2 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL-03-04-04 19 47 57.5 17 10 19 47 57.5 10 24 50
Local Area: (800) 258-9200-www.stevenengineering.com 01 02 03 Type of actuation 2 position single (A) 4 (B) 2 1 Manual override 5 (R1) 1 (P) 3 (R2) B: Locking type (Tool required) Nil: Non-locking push type (Tool required) 2 position double (A) 4 (B) 2 (A) 4 (B) 2 2 1 (P) 3 (R2) 5 (R1) Metal seal Rubber seal 1 (P) 3 (R2) 5 (R1) 3 position closed center (B) 2 (A) 4 3 5 (R1) 1 (P) 3 (R2) Electrical
Joint MU Applicable mounting bracket Bore size (mm) Joint 2 x D through T1 J E 2 x O counter bore Type A mounting bracket Type B mounting bracket B 32, 40 YU-03 YA-03 YB-03 50, 63 YU-05 YA-05 YB-05 Material: Stainless steel mm 80 YU-08 YA-08 YB-08 100 YU-10 YA-10 YB-10 Bore size (mm) O M J E D B Part no.
Hs A B A B Proper Auto Switch Mounting Position Auto Switch Mounting Height D-A7H D-A80H D-F7 D-A7H, A80H D-A73C, A80C D-F7, F7V D-F79F, J79 D-J79C, F7W D-F7WV, J79W D-F7BAL, F7BAVL D-J79W D-F7BAL D-F79F D-F7NTL D-F7V D-A7 D-A80 D-A73C D-A80C D-J79C D-A79W D-F7WV Bore size (mm) D-A7, A80 D-A79W D-F7NTL Bore size (mm) D-J79 D-F7W D-F7BAVL Hs Hs Hs Hs Hs Hs 20 A B A B A B A B 25 20 32 25 31.5
(mm) a b Effective area (mm2) Weight (g) D L M2 Model 3.2 4 KJH02-23 KJH02-04 8.4 9.3 26.6 26.6 8.8 8.8 12.7 12.7 0.9 0.9 2.4 3.2 2 M1 M2 D D L Applicable tubing a Applicable tubing b Male elbow: KJL T H A Applicable tubing O.D.
B K P C C C U K P O A A S H L to C U S O H L to B D !
AV*-OMZ0091-A PRODUCT NAME Soft Start-up Valve MODEL / Series / Product Number AV2000-(F,N)02(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV3000-(F,N)03(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV4000-(F,N)04(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV5000-(F,N)06~10(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AVA2000-(F,N)02(B,G,S)(-R,Z)-A AVA3000-(F,N)03(B,G,S)(-R,Z)-A AVA4000-(F,N)04(B,G,S)(-R,Z
Series VS R8 S HOW TO ORDER ISO5599/2 VALVE MANIFOLD VV8 2 5 03 TU1 03 D T W1 W1=NEMA 4 ISO Size Port Thread Code 1 Size 1 2 Size 2 3 Size 3 NIL Rc (PT) T NPTF F G(PF) Location of port 1(P), 5(EA), 3(EB) Number of Stations D D side 2 2 stations U U side B Both side 9 9 stations Size of port 1(P), 5(EA), 3(EB) Symbol Size Applicable ISO size 02 1/4 Size 1 U side option 03 3/8 Size 1
A: Orange B: Green U D Note) The dimensions L1 to L4 are identical to SS5X3-45F Station (P . 1-6-92).
VXD2130 Coil with a full-wave rectifier (electrical option R) 10 Series VXD21/22/23 Dimensions Normally closed (N.C.): VXD2140/2150/2260 Normally open (N.O.): VXD2142/2152/2262 Conduit: C Grommet: G Q L Approx. 280 Q L M Approx. 300 G1/2 N f N B OUT IN 1 E C F H 2-P Port size D 2 x 8.5 a b e Conduit terminal: T d K J (Q) L A (Q) L DIN terminal: D 32 (44) N N G 1/2 G1/2 Cable 6 to 12 E R
Due to meter-in control, the cylinder moves from A to B regardless of whether it is an initial operation or a normal operation. When it reaches B, the head pressure (PH) rises quickly as indicated by the line from C to D.
(3) (a) EMC HF3010A-UN [:mm] 4-5.5 7 3-M4 3-M4 M4 32 2 110 4 85 2 IN (41) 258 4 65 4 273 2 288 4 300 5 HF3030A-UNHF3040A-UN [:mm] 6-K 3-L 3-L G 1 D 2 E 1 F 2 M J 2 C 1 C 1 H 2 B 2 A 5 [mm] A B C D E F G H J K L M HF3030A-UN 260 210 85 155 140 125 44 140 70 R3.25 8 M5 M4 HF3040A-UN 11 30 11.
CM3 Auto Switch Proper Mounting Position (Centralized piping type, With end lock) CG1 (mm) Auto switch model D-H7l D-H7C D-H7lW D-H7BA D-H7NF CG3 D-C7l D-C80 D-C73C D-C80C D-G39A D-K39A D-A3lA D-A44A D-M9l(V) D-M9lW(V) D-M9lA(V) D-A9l(V) D-G5NT D-B5l D-B64 D-B59W JMB MB A B A B A B A B A B A B A B A B Bore size MB1 20 10.5 (8) 9.5 (7) 6.5 (4) 5.5 (3) 0.5 () 0 () 6 (4) 5 (3) 2.5 (0.5) 1.5
1 A Q a q 0 0 1 0 2 STX DC2 2 B R b r 0 0 1 1 3 ETX DC3 # 3 C S c s 0 1 0 0 4 $ 4 D T d t 0 1 0 1 5 % 5 E U e u 0 1 1 0 6 & 6 F V f v 0 1 1 1 7 7 G W g w 1 0 0 0 8 ( 8 H X h x 1 0 0 1 9 ) 9 I Y i y 1 0 1 0 10 : J Z j z 1 0 1 1 11 ; K [ k { 1 1 0 0 12 , L l | 1 1 0 1 13 M ] m } 1 1 1 0 14 . N ^ n 1 1 1 1 15 / ?