Remarks Sensor connector (For PFMB) ZS-28-C-1 Sensor connector (For PFMC and PF3A7) ZS-28-CA-4 Bracket A ZS-46-A1 Self tapping screws: Nominal size 3 x 8L (2 pcs) Bracket B ZS-46-A2 Self tapping screws: Nominal size 3 x 8L (2 pcs) Panel mount adapter ZS-46-B Panel mount adapter + Front protective cover ZS-46-D Lead wire with connector ZS-46-5L 5 cores, 2 m Front protective cover ZS-27-01
Stop Ensure that the circulating fluid flow is 5l/min.or more. Check the heat load are within the specified range. AL06 High circulating fluid discharge pressure Stop Check the user's piping for bends, squash and foreign matters. AL07 Abnormal pump operation Stop Restart and check the pump is operating.
Stop Ensure that the circulating fluid flow is 5l/min.or more. Check the heat load are within the specified range. AL06 High circulating fluid discharge pressure Stop Check the user's piping for bends, squash and foreign matters. AL07 Abnormal pump operation Stop Restart and check the pump is operating.
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: S (5VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: S (5VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: H (Grommet Lead Wire 0.6m), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: V (6VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: R (Surge Suppressor, Non-polar), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: MN (M Plug Connector w/o Lead Wire), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: S (5VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: S (5VDC), Lead Wire: H (Grommet Lead Wire 0.6m), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: B (Locking Slotted), Port Size: M5 (With Sub-Plate)
Type of Actuation: 2 (Normally Open), Flow Capacity: A (Large Flow), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: LN (L Plug Connector w/o Lead Wire), Surge Suppressor: None, Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)