SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
II Air Cylinder Drive Systems Total Stroke Time and Speed at the End Series SV Series SV1000 Applicable bore size: 20, 25, 32, 40 Applicable related components Total stroke time s Solenoid valve Tubing Speed controller Silencer 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 200 CM2 20 50% 70% 10% 30% 150 Stroke mm AS2201F -01-06 AS2200-01 70% 100 50 10% 30% 50% 0 200 CM2 25 150 Stroke mm AS2201F
Internal wiring 1 3 5 6 M5 C4 C6 VZ323MOZApplicable valve model Rated voltage 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Note ) Withstand voltage specifications of wiring unit part is equivalent to JIS C 0704 class 1.
(Valve) SYJ500-10-1A .1 pc. (Blank plate ass'y) VQ SS3YJ5-41R-03-C6 .1 pc. (Manifold base) SYJ514R-5G .2 pcs. (Valve) SYJ500-10-3A . 1 pc.
Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Made to Order Specifications (For details, refer to page 4-6-46.)
(Appropriate tightening torque is 1.2 to 1.6Nm) Caution Enclosure IP65 Manifold block assembly VQ1000 VVQ1000-1A-2-C3 VVQ1000-1A-2-C4 VVQ1000-1A-2-C6 VVQ1000-1A-2-M5 Port size Wires, cables, connectors, etc. used for models conforming to IP65 should also have enclosures equivalent to or of stricter rating than IP65.
Bore size CJ2 series Pressure 0.5 MPa Load ratio 50% Stroke 60 mm CM2 series Pressure 0.5 MPa Load ratio 50% Stroke 300 mm CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] 6 10 16 125 140 160 180 200 250 20 25 32 40 40 50 63 80 100 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward
Bore size 16 20 25 32 40 50 63 16 20 25 32 40 50 53 Recommended length Part No.
Stations3 2 1 (For single solenoid) Connector assembly Common specifications SX3000-23-1A P Positive common N Negative common SS5X3-20P-061 set (Type 20P , 6-station manifold no.) SY3000-26-10A1 set (Blanking plate assembly part no.) SX3120-5MOZ-C6 3 sets (Single solenoid part no.) SX3220-5MOZ-C6 2 sets (Double solenoid part no.) SX3000-23-1A 3 sets (Connector assembly no.)
fitting for5/16 Gasket 6 is supplied as an accessory. 1 Manifold block assembly SX3000-50-1ASX5000-50-1ASX3000-51-1A (Metric size) SX5000-51-1A (Metric size) SX5000-51-15A (Inch size) P,R port SY3000(Metric size):With one-touch fitting for8 (Inch size):With one-touch fitting for5/16 P,R port SY5000(Metric size):With one-touch fitting for10 (Inch size):With one-touch fitting for3/8 2 SUP/
VVQC 000 3A 1 1 VVQC 000 1A 1 D C6 Series Series SV 1 2 1 2 VQC1000 VQC1000 SYJ VQC2000 VQC2000 Note) Tie-rods (2 pcs.) for additional stations included.
Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve M5 C4 C6 M5 C4 C6 SS5YJ520 05 SYJ520-A, B port M5 x 0.8 SYJ523-Applicable blanking plate assembly SYJ5000-21-1A Applicable individual EXH spacer assembly SYJ5000-17-1A P, R port thread type Number of stations -+ -+ P port 1/8 02 2 stations R R P Nil 00F 00N 00T Rc G NPT NPTF : : 20 20 stations R port 1/8 Type 40 (5 Port/
220 VAC 50/60 Hz [230 VAC 50/60 Hz] 4 For type W, only DC voltage is available.
Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical
Example: SS3YJ5-20-03 .1 set (Manifold base) SYJ512-5LZ-M5.2 sets (Valve) SYJ500-10-1A.1 set (Blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (Manifold base) SYJ514R-5G.2 sets (Valve) SYJ500-10-3A .1 set (Blanking plate assembly) The asterisk denotes the symbol for assembly.
SZ3000-73-1A-L4 SZ3000-73-1A-L6 SZ3000-73-2A-L4 SZ3000-73-2A-L6 SZ3000-56-1A VVQ1000-51A-C6 VVQ1000-51A-C8 SZ3000-74-1A-L6 SZ3000-74-1A-L8 SZ3000-74-2A-L6 SZ3000-74-2A-L8 4(A), 2(B) port 1(P), 3(R) port Other Tube Brands Caution 1.
SZ3000-73-1A-L4 SZ3000-73-1A-L6 SZ3000-73-2A-L4 SZ3000-73-2A-L6 SZ3000-56-1A VVQ1000-51A-C6 VVQ1000-51A-C8 SZ3000-74-1A-L6 SZ3000-74-1A-L8 SZ3000-74-2A-L6 SZ3000-74-2A-L8 4(A), 2(B) port 1(P), 3(R) port Other Tube Brands Caution 1.
Internal wiring 1 3 5 6 01 C6 C8 VZ523MOZ-VZ3Applicable solenoid valve 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Rated voltage Note) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 16 for power consumption of AC type.
fitting assembly VQC 1/2 C8: 8 One-touch fitting assembly C6: 6 One-touch fitting assembly 2 x Rc 1/8, 1/4, C6, C8 23 P = 22 L1 L2 L3 ( 9.5) ( 9.5) 80 39.5 (For C6, C8) (For C6, C8) (For C6, C8) ( 9.5) VQC 4/5 DIN rail clamp screw 2 x M4 mounting hole 4.5 2 x M6 mounting hole VQZ IN IN IN IN 37.5 5.5 SQ (5) 69.5 (40) 6.5 58 10.5 80 Residual pressure release manual override VFS (For C6, C8