(Maximum 10 stations) Example) IITV00-05-07 Stations IITV00-031 set (Manifold part no.)
Contents Bore size (mm) 40 50 63 80 100 MBW40-PS MBW50-PS MBW63-PS MBW80-PS MBW100-PS #8 #9 40 Piston seal NBR Rod seal A NBR Set of left nos. #8, #9, $2, $4 Rod seal B NBR 41 $2 43 $4 45 Release piston seal NBR 40, 41, 43 and 45 to 48 are non-replaceable parts, so they are not included in the seal kit.
Box type (Built-in silencer) B S 07 ZH 06 06 Body ported type (Without silencer) D S 07 ZH 01 01 01 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com EXH. port size Note) Nozzle diameter Symbol Size Style One-touch One-touch One-touch One-touch One-touch Screw-in Screw-in
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
DC: 0.45 W (With indicator light: 0.5 W) Y 13-2-43 43 Series ZX Valve Unit: ZX1-VB Refer to page 13-2-10 for details. Specifications Unit no. ZX1-VB Components Vacuum switch valve Vacuum release valve Direct operated type Pilot type Solenoid valve Solenoid valve Air operated N.C. (VJ114) N.O. (VJ324) N.C. (VJ114) N.C.
(mm) a b Note 2) Effective area (mm2) W Note 1) D W Weight (g) L1 L2 P M1 M2 N O Model P 3.2 4 6 8 10 12 4 6 8 10 12 16 KQB2U23-04 KQB2U04-06 KQB2U06-08 KQB2U08-10 KQB2U10-12 KQB2U12-16 3.2 3.2 4.2 4.2 4.2 4.2 5.6 5.6 8 8 8 8 3.2 4.2 13.4 25.6 40 57.4 8.5 11.9 19.3 32 47.6 67.6 9.1 11.4 13.7 16.6 18.7 24.6 27 29.3 33.7 38.3 43 47.4 10.8 11.2 12.2 13.8 14 15.6 8.1 9.1 11.5 14.6 17.6 19.8 16.4
Refer to front matters 42 and 43 for Safety Instructions, and pages 17 to 19 for 2 Port Solenoid Valves for Fluid Control Precautions. Light / Surge Voltage Suppressor M12 Connector Caution Caution
) 82 0.1 0.2 6 0.3 43 (34) 39 (30) 35 (28) 54 2) 49 (41) 53 (50) 47 (43) 68 0.5 67 (64) 61 (59) 54 (51) 81 1) ( ) 2) ZQ05A0.35MPaZQ07AZQ10A0.43MPaZQ000A0.4MPa 3) (PD) V PD [MPa] ZQ05A ZQ07A ZQ10A ZQ000A 0.05 11 10 8 16 0.15 22 20 17 32 3.2 0.25 31 29 24 46 0.35 44 39 31 60 0.45 54 48 38 74 0.05 11 11 9 16 0.15 24 22 18 33 4 0.25 34 32 27 48 0.35 46 42 35 62 0.45 57 52 44 76 0.05 12 11
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
Purchasing order is available in units of 10 pieces. d d KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.
VF KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 VP4 VQ 1/2 VQ 4/5 Port plug VVQ1000-58A VQC 1/2 VQC 1/2 The plug is used to block the cylinder port.
CH1-07 CH2-07 Reservoir High Level WRN Continued Drain the circulating fluid. Check the load specification. Replacement of the thermal fuse is required. Call the supplier for service. CH1-08 CH2-08 Temp. Fuse Cutout FLT Stop The circulating fluid tank was raised in temperature. The temperature of the circulating fluid exceeded the specified value.
VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size 2.5 3 3.5 2.5 3 3.5 2.5 3 3.5 2.5 3 3.5 01 02 03 04 05 06 07 11 12 13 21 22 23 24 31 32 33 34 35 36 37 38 41 42 43 44 45 46 47 48 49 50 51 52 23.4 23 22.5 22.1 22 Nozzle length: 100 mm 98
Refer to front matters 42 and 43 for Safety Instructions, and pages 507 to 509 for High Purity Chemical Air Operated Valve/Compact Type Precautions.
An excessive amount of the circulating fluid is observed in the tank. 07 Reservoir High Level WRN Continued Drain the circulating fluid. The circulating fluid tank was raised Check the load specification. Replacement of the thermal fuse is required. Call the supplier for service. in temperature. 08 Temp.
PA 02 200 VAC 50/60 Hz 01 100 VAC 50/60 Hz 08 48 VAC 50/60 Hz 01 02 03 04 07 08 05 06 002 Applicable valve model No. 13 24 VAC 50/60 Hz VXZ22 VXZ23 03 110 VAC 50/60 Hz 23 440 VAC 50/60 Hz PAX 003 AC 04 220 VAC 50/60 Hz 51 6 VDC Coil combination code 05 24 VDC 53 48 VDC PB 06 12 VDC 55 100 VDC 56 110 VDC (Refer to the table below.) 07 240 VAC 50/60 Hz DC Note) The voltage codes
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.