Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1C, L2C L2C B1/ + External regenerative resistor connection terminal L2 LEC Y LEC Y Motorless L3 When the regenerative resistor is required, connect it between terminals B1 + and B2.
H1 C NA D E MM AL A H ZZ + Stroke S + Stroke NA C 4 x J Female thread MM Depth A1 H ZZ + Stroke Female rod end Female Rod End [mm] [mm] Bore size A AL B1 C D E F H H1 J KA MM NA Bore size A1 H MM 20 14.5 12 13 15.5 8 14 0 0.1 2 21 5 M4 x 0.7 depth 7 Width across flats 6 length 3.5 M8 x 1.25 24 20 8 6.5 M4 x 0.7 25 17.5 15 17 16.5 10 14 0 0.1 2 24 6 M5 x 0.8 depth 7.5 Width across flats 8
When actually mounting the auto switch, adjust the position after confirming the operating conditions of the auto switch. 47 Air Cylinder 2122CA2/ CA2 1011Basic style (B) / CA2B, CA2B 10112122Relief port 2-cushion valve M5 x 0.8 4-J GA 6 Width across flats KA 2-RcP GB Width across flats B1 E D MM H1 AL C H S + Stroke 7 18 K N A N M ZZ + Stroke B (mm) AL Bore size Stroke range Symbol B B1
Fittings & Tubing Air Cylinders Rotary Actuators 2 x P (Rc, NPT, G) H2 Width across flats B2 2 x NN G Relief port M5 x 0.8 G H1 Width across flats B1 Standard port I Relief port 2 x Eh8 D MM AL A F K NA N N H S + Stroke F ZZ + Stroke (mm) ZZ S P N I E D A 12.5 11 10 10 13 F Bore size Stroke range AL K MM NA NN G H2 41 32 32 26 B2 H H1 22 17 17 13 B1 0 6 6 5 8 8 8 50 45 45 41 200 to 1000 150
95.5 24.5 115.5 44.5 115.5 MX D-M9, D-M9V (mm) Mounting pattern q Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 MTS Operating range B1 A1 B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 MY 5 35 70 23 82 35 82 5 40.5 99.5 28.5 111.5 40.5 111.5 CY Mounting pattern w B2 A2 D-F9W, D-F9WV MG (mm) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA
Problem Presumed cause Troubleshooting In IO-Link mode, IO-Link device LED (C/Q) of EX600L#B1 is flashing green (1Hz). Connect the IO-Link device. disconnected. In IO-Link mode, Connected IO-Link Check the setting of Validation and Backup. Check the process data of each port of the IO-Link LED (C/Q) of EX600L#B1 is flashing green (2 Hz). device matching error. master.
Output data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 D4 #D3 #D2 #D1 #C4 #C3 #C2 #C1 #B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 Slave 8 connection diagnosis 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 In the figure above, #A1 to #A3 are slaves for which the connection is diagnosed. In this case, #A3 slave is not connected, and a diagnostic error is generated.
B1 VAR U B DC24V VAR U B DC24V B2 B2 B1B2(VAR) (2) (3) (a) R[]:() L[H]:() Vb[V]: DC24V U Vs[V] N () 14.1.2 14 2 14.
IZN10E CP Bracket Power supply cable Symbol Type B1 L-bracket B2 Pivoting bracket B3 DIN rail mounting bracket Symbol Type Nil 3 m Z 10 m Power supply cable: Made to order IZN10E CP X13 01 L-bracket IZN10-B1 Pivoting bracket IZN10-B2 Power supply cable length Symbol Type 01 1 m 20 20 m * Available in 1 m increments from 1 m to 20 m.
LEC CN5 1 (8.9) B1 A1 A1 Cable length (L) [m] (22.4) A13 1 1.5 3 3 5 5 B1 (14.4) L B13 B13 A13 Connector pin no.
Basic (B): CG1WB 1011With rubber bumper 2 x M5 x 0.8 Relief port F GA F GA Port on rod end Port on rod end Width across flats KA 2 2 Width across flats KA RA RA 2 x Rc P 1 1 0 E0.05 MM H1 H1 MM D D I 0 E0.05 C R0.4 R0.4 ZZ + 2 Stroke S + Stroke H A AL Width across flats B1 Width across flats B1 H + Stroke A AL K K 8 x J NA C Female rod end effective depth A1 MM ZZ + 2 Stroke H + Stroke H
Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Brown 1 Sensor (+) B-3 Blue 2 Sensor (-) A-3 Actuator side Controller side 2 1 (5.5) (6.3) (1) (14) (18) B1 A1 6 (2) 5 (17.7) (14.2) A6 B6 (3) 2 (10.2) 1 B1 A1 B3 A3 15 16 -56No.
B B-6 Orange 9 B A-6 Black 8 3 (4) Signal name Terminal number Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Brown 1 Sensor (+) B-3 Blue 2 Sensor (-) A-3 Actuator side Controller side 2 1 (5.5) (1) (2) (6.3) (14) (18) B1 A1 6 5 (17.7) (14.2) A6 B6 2 (10.2) 1 B1 A1 B3 A3 (4) (3) (5.7) 15 16 L (11) (30.7) -60No.
Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Brown 1 Sensor (+) B-3 Blue 2 Sensor (-) A-3 Actuator side Controller side 2 1 (5.5) (6.3) (1) (2) (14) (18) B1 A1 6 5 (17.7) (14.2) A6 B6 2 1 (10.2) B1 A1 B3 A3 (3) (4) (5.7) 15 16 L (11) (30.7) -60No.
Red 4 Lock(+) B-1 Black 5 Lock(-) A-1 Brown 1 Sensor(+) B-3 Blue 2 Sensor(-) A-3 Actuator side Controller side (8) (1) (2) (14.2) B1 A1 2 1 (17.7) (14) (18) 6 A6 B6 5 (10.2) A1 B3 A3 (4) B1 1 2 (5.7) 15 16 (3) L (11) (30.7) [4] Actuator cable for actuator with lock (for sensor and lock) [8 20m] LE CP B (1) (2) Cable color Terminal No. Signal name Terminal No.
2 6 B A-2 5 COM-A/COM B-3 3 COM-B/ A-3 4 3 Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 (4) + B-1 4 A-1 5 + B-3 1 A-3 2 8 (14.2) 1 2 (2) B1 A1 17.7 1 (14) A6 B6 5 6 10.2 (3) 1 2 A1 B1 (18) 5.7 A3 B3 4 15 16 (11) 30.7 L 15.4 ()[820m] 1 2 LE CP B 2 A B-1 L 1 A A-1 6 B B-2 8 8m * 5 B A-2 3 COM-A/COM B-3 A 10m * 4 COM-B/ A-3 B 15m * 3 Shield C 20m
B A B-1 2 A A-1 1 (L) B (B-2) 6 B (A-2) 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 (3) 5 5m Shield Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 B (B-6) 9 B (A-6) 8 3 (4) S 4 (+) B-1 5 (-) A-1 1 (+) B-3 2 (-) A-3 (8) (1) (2) (B1) A1 (14.2) 2 1 (17.7) (14) (18) 6 (10.2) A6 B6 5 (3) B1 A1 2 1 (B3) (A3) (5.7) (4) 15 16 L (11) (30.7) 15.4 ()[820m] (1) (2) LECPB A B-1 2
A6 B6 (10.2) 2 1 B1 A1 B3 A3 (d) (18) (5.7) 16 15 L (11) (30.7) -88No.
(b) L E C P * B -* A B-1 2 A A-1 1 L B B-2 6 B A-2 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 (c) 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 (d) S 4 + B-1 5 A-1 1 + B-3 2 A-3 (8) (a) (b) (14.2) B1 A1 (17.7) 2 1 (14) (18) 6 (10.2) B6 5 A6 2 1 B1 A1 B3 A3 (d) (5.7) 15 16 (c) L (11) (30.7) 12.6 ([820m] (a) (b) LE CP * B A B-1 2 A A-1 1 L B