SMC Corporation of America
Elite Part Number Search
Search Results "RZQA63TN-200-60"

Single clevis: CP96NC Double clevis: CP96ND CD EB UB CB EW MR L XD + Stroke Double clevis Single clevis [mm] Bore size CBH14 CDH9 EB EW L MR UBh14 XD 32 26 10 65 26 0.2 0.6 12 9.5 45 200 40 28 12 75 28 0.2 0.6 15 12 52 226 50 32 12 80 32 0.2 0.6 15 12 60 245 63 40 16 90 40 0.2 0.6 20 16 70 269.5 80 50 16 110 50 0.2 0.6 20 16 90 320 100 60 20 140 60 0.2 0.6 25 20 110 353.5 Pivot Bracket: Double

156 180 181 205 206 230 231 255 40 Up to 200 63.5 14 49 22 18 10 6.6 40 4.5 (58.4) 56 30 30 71.4 175 200 200 228 225 253 250 278 For dimensions of pivot bracket, refer to page 309.

VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option 3-5-94 95 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR6000 Cylinder Speed Chart Use as a guide for selection.

It is already built-in to the rectifier circuit. 50 60 100 VAC Hz 1 2 200 VAC Hz 50 60 50 60 110 VAC Hz [115 VAC Hz] 3 Electrical entry 50 60 50 60 50 60 DIN terminal D With connector 4 220 VAC Hz [230 VAC Hz] DO Without connector DC specifications of type "D" and "DO" is only available with 12 and 24 V DC. Power saving circuit is not available in the case of "D", "DO" type.

Hz L plug 25 2500 mm LN Without lead wire 2 200 VAC 50/60 Hz connector 30 3000 mm LO Without connector 110 VAC 50/60 Hz 50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.

(mm) Bore size (mm) Stroke range (mm) AL AK AP AJ AI AH AG N AB M AA L K J I V B U T A O P S 63 80 100 12 14 60 180 158 250 228 100 25 66 25 180 135 117 65 108 228 192 30 M12 x 1.75 depth 23 Rc 1/4 200 72 75, 100, 125 150, 200, 250 300 16 14 70 200 178 284 262 115 27 76 30 214 160 138 75 128 262 224 M12 x 1.75 depth 28 Rc 3/8 35 230 89 16 16 80 226 200 326 300 125 30 80 32 245 190 153 85

0 100 200 300 400 500 600 700 0 50 100 150 200 250 0 50 100 150 200 250 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) NOTE) Contact SMC for details of ARBY7000 (New) 1.2-182 5 Port Solenoid Valve/Body ported Cassette Type Manifold Series SY3000 / 5000/7000 SV SY SY SYJ SX VK Series SY7000 VZ VF VFR VP7 VQC Series SY5000 SQ VQ VQ4 VQ5 VQZ VQD Series

Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC [115 VAC] (50/60 Hz) 220 VAC [230 VAC] (50/60 Hz) 24 VDC 12 VDC Note) For sub-plate part no., refer to page 967.

200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000 25 Refer to pages 101 to 111 for cylinders with auto switches.

300 st 30 st or less Over 30 st 100 st or less Over 100 st 200 st or less Over 200 st 300 st or less Over 300 st 12 13 8 18 14 48 22 56 41 50 37 20 40 110 200 15 25 60 105 23 3 3.5 M5 x 0.8 10 5 16 14.5 10 19 16 54 25 62 46 56 38 24 44 110 200 17 27 60 105 24 3 3.5 M5 x 0.8 10 5 20 13.5 10.5 25 18 70 30 81 54 72 44 24 44 120 200 300 29 39 77 117 167 28 3 3.5 M6 x 1.0 12 17 25 12.5 13.5

7 5.5 32 2 14 44 40 Up to 200 7 6.6 38 2 18 53 40 Up to 200 8 6.6 46 2 25 61 50 End boss is machined on the flange for E.

60 70 70 0 0 40 80 120 160 200 100 200 300 Outlet air flow rate (l/min (ANR)) Outlet air flow rate (l/min (ANR)) IDG100L (Type B products group) Refer to pages 14-19-28 to 29.

15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available by the 1 mm interval with no stroke adjustment by spacer.

Calculation Example: CLJ2L16-60 Basic weight320(16) Additional weight6.5/15 stroke Cylinder stroke60 stroke 320+6.5/15 X 60+27=373g 3 2 1 0 50 100 200 300 400 500 Piston speed (mm/s) Stopping Accuracy (Not including tolerance of control system) Unit: mm Lock style Piston speed (mm/s) Holding Force of Spring Lock (Maximum static load) 50 100 300 500 16 Bore size (mm) 0.4 0.5 1.0 2.0 Spring

mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 R TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE1 US C R C US US C R R R R R R R US C US C US C US C US C US C SERIAL NO.

SY3000 SY30M-60-1A SY5000 SY50M-60-1A SY7000 SY70M-60-1A Intermediate stop Drop prevention With Residual Pressure Release Valve Applicable valve SY 3 5 7400 1 SY 3 5 7 1 200 1 EXH. 2(B) 4(A) 3(EB) 1(P) 5(EA) Circuit diagram Vacuum Release Valve with Restrictor (Intermediate stop: When 3-position exhaust center valve is mounted) Mounting screw Double check spacer assembly with residual pressure

60 70 70 0 0 20 40 60 80 100 160 40 80 120 Outlet air flow rate l/min (ANR) Outlet air flow rate l/min (ANR) IDG75L IDG60L 0 0 P1 = 0.3MPa Outlet air atmospheric pressure dew point C Outlet air atmospheric pressure dew point C P1 = 0.3MPa 10 10 20 20 P1 = 0.5MPa P1 = 0.5MPa 30 30 40 40 P1 = 0.7MPa P1 = 0.7MPa 50 50 60 60 70 70 0 0 40 80 120 160 200 100 200 300 Outlet air flow rate l/min

DC 99 100 60 40 40 60 80 60 -10 Note 2) 60 40 1 AC DC AC, DC Note) Surge voltage suppressor is attached to the lead wire. Maximum Minimum -10 -5 Note 3) Note 1) D.E.N.P., etc., inside ( ) indicate option codes. Note 2) Dew point is -10C or below.

psig (1.4 MPa) AP1600 100 psig (0.69 MPa) 60 psig (0.41 MPa) Inlet pressure: 80 psig (0.55 MPa) 100 0.69 60 0.41 90 0.62 50 0.34 80 0.55 Delivery pressure (MPa) Delivery pressure (MPa) Delivery pressure (psig) Delivery pressure (psig) 70 0.48 40 0.28 60 0.41 50 0.34 30 0.21 40 0.28 20 0.14 30 0.21 20 0.14 10 0.07 0 10 0.00 0.07 0 0.00 0 100 200 300 400 500 600 Flow rate (slpm, N2) 0 50 100

341 100 76 56 32 12.5 25 37.5 50 75 100 125 150 175 200 225 250 103 116 128 141 166 191 216 241 266 291 316 341 125 82 75 40 10 20 30 40 60 80 100 120 140 160 180 200 130 140 150 160 180 200 220 240 260 280 300 320 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 901 to 1000 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301