SMC Corporation of America
Elite Part Number Search
Search Results "RS2H63TN-30TM-DP-M9PVSDPCS"

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 075 (3/4in), Stroke: 0300 (3"), Cushion: C (Rubber Bumper), Rod Boot: Without Boot, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: S (1 pc.)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 12mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector

Magnet: D (Built-in), Mounting: A (Both Ends Tapped; 40 Through 63 Bore), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length,

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Stroke: 10mm, Action: Single Acting, Spring Extend, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 1 pc.

Magnet: Built-in, Mounting: Rod Flange, Bore Size: 160mm, Port Thread: G, Stroke: 200mm, Rod Boot: None, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 1 pc.

Magnet: Built-in, Rod Type: Standard, Mounting: Both Ends Tapped, Bore Size: 32mm, Stroke: 20mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 1 pc.

Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 40mm, Stroke: 20mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 1 pc.

Magnet: Built-in, Rod Type: Standard, Mounting: Both Ends Tapped, Bore Size: 12mm, Stroke: 10mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 1 pc.

Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Stroke: 10mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 1 pc.

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 5, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Bearing Style: Slide Bearing, Bore Size: 20mm, Port Thread: Bore 6-25: M Thread; Bore 32: Rc, Piping: Standard Porting, Stroke: 100mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 1 pc.

No.EX##-OMO0019 PRODUCT NAME PROFIBUS DP Compatible Fieldbus System MODEL / Series / Product Number EX500-GPR1A etc.

Element Description Connect to PROFIBUS DP line with a communication connector for PROFIBUS DP ( ).

Communication connection to the master is established PROFIBUS DP address setting and Fail safe setting (SETTINGS) DP address setting (ADDRESS)> Set the PROFIBUS DP address of the SI unit in binary coded form with 8-element switch. Address range is 1 to 125. Note: Factory default setting is Address 1.