Blue DC() -26 Analog output type 1 to 5V (2.5% F .S.) Output impedance: 1k Bring the pressure back to atmospheric pressure and try using the zero out function. Residual pressure error Brown DC(+) Black OUT (Analog output) + 12 to 24VDC Load Blue DC() Supply pressure exceeds the maximum regulating pressure. -28 Analog output type 4 to 20mA (2.5% F .S.)

RSH20, 32 Graphq Graphw 1.0 RSH20 RSH32 0.9 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 Operating pressure P [MPa] 0.8 1300 1300 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 600 600 0 500 100 200 300 400 63 Lateral load F [N] 500 500 50 400 400 RS1H50, 63,

For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire

Indicator/Pilot port direction XMA Rear flange surface XYA Symbol Nil A F J K M Rear flange surface Indicator Without indicator Pilot port direction Indicator Without indicator Pilot port direction Symbol Nil A F G J K L M Right flange surface Left flange surface Right flange surface Left flange surface Rear flange side Rear flange side Left flange surface Right flange surface Left flange

(Example) Step data on the PC (controller setting software) screen [Normal mode] Speed Position Accel Decel PushingF T riggerL V PushingSp Moving F Area1 Area2 In pos No.

Basic (Through-hole/Both ends tapped common): CQUB F Q 2 x M5 x 0.8 Y 4 x M6 x 1 depth 10 4 x 5.4 through 15 KA H H1 Rod end nut Width across flats B1 NY EY D X C1 K NX A + Stroke B + Stroke L EX L1 Rod end male thread Basic (mm) Size Stroke range (mm) A B D EX EY F H K KA L NX NY Q Y 20 25 32 40 5 to 50 49 42.5 10 22 47 11.5 M5 x 0.8 depth 8 5 8 6.5 5.5 36 15 3 5 to 50 49 42.5 10 24 53 11

Mounting clearance (mm) Bore size (mm) 40 20 46 25 56 32 Clearance 6 Series CU Auto Switch Specifications Auto Switch Common Specifications Type Reed switch Solid state switch Leakage current None 3-wire: 100A or less; 2-wire: 0.8mA or less Operating time 1.2ms 1ms or less Impact resistance 300m/s 50M or more at 500VDC (between lead wire and case) 1000m/s Insulation resistance 1500VAC for

Reference formulas [Dynamic moment at impact] Use the following formulas to calculate dynamic moment when taking stopper impact into consideration. m F FE a M 1.4 = 1.4a (mm/s) FE = agm Note 4) 100 1 ME = FE L1 = 0.05a m L1 (Nm) Note 5) L1 ME g : Load mass (kg) : Load (N) : Load equivalent to impact (at impact with stopper) (N) : Average speed (mm/s) : Static moment (Nm) : Impact speed

If the variable orifice is closed (turn the adjustment knob counterclockwise), all LED's are off. d When opening the variable orifice (turn the adjustment knob clockwise) the LED's will light up in the following order: Red 1, Red 2, Green 1, Green 2 f When the LED Green 1 is on, the output is energized.

Set value correction by auto shift function Supply pressure normal Supply pressure drop Supply pressure increase F Reset function P-1 C-5 C-5 (P-3) (Differential) Pressure This function clears and resets the zero value on the display of measured (differential) pressure within 7%F.S. of the factory adjusted value.

SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.

How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)

Size, Body, Valve Type: 50M (Size: 2; Body Mat'l: Resin; Port Size ø10 One-touch Fitting; Orifice Dia: 7, N.O.), Voltage and Electrical Entry: F (24VDC; Grommet w/Surge Voltage Suppressor)

Mounting clearance (mm) Bore size (mm) 40 20 46 25 56 32 Clearance 6 Series CU Auto Switch Specifications Auto Switch Common Specifications Type Reed switch Solid state switch Leakage current None 3-wire: 100A or less; 2-wire: 0.8mA or less Operating time 1.2ms 1ms or less Impact resistance 300m/s 50M or more at 500VDC (between lead wire and case) 1000m/s Insulation resistance 1500VAC for

Developed to be combined with our extensive line of fittings, the addition of the TILM tube provides a complete solution for your piping equipment needs., FLUOROPOLYMER,TUBING NAT 50M, TUBING, FLUORO. TL/TIL, TD/TID, TH/TIH, H09, 9.64 lb

(Example) D-Y7NWL Impact resistance . 1,000m/s (102G) Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage . 1000VAC for 1 min. (between lead wire and case) Ambient temperature ... 10 to 60C (14 to 140F) Enclosure .

(Example) D-Y7NWL Impact resistance . 1,000m/s (102G) Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage . 1000VAC for 1 min. (between lead wire and case) Ambient temperature ... 10 to 60C (14 to 140F) Enclosure .

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 50mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)