Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: TSJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: Rc 1/8, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: N02 [NPT 1/4 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
PSE561 and 562 are remote pressure sensors with an analog V or mA signal output. PSE56* sensors measure pressure of any liquid or gas non-corrosive to 316L stainless steel. PSE561 is for low vacuum (-101 to 0 kPa), while PSE563 is for compound pressure (-100 to 100 kPa). The accuracy and construction are suitable for general purpose applications.
PSE561 and 562 are remote pressure sensors with an analog V or mA signal output. PSE56* sensors measure pressure of any liquid or gas non-corrosive to 316L stainless steel. PSE561 is for low vacuum (-101 to 0 kPa), while PSE563 is for compound pressure (-100 to 100 kPa). The accuracy and construction are suitable for general purpose applications.
Please contact us for the latest version.sales@ocaire.com, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, JC, PSE5*1 VAC SWITCH 1/8 PORT PT, .66138 lb
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: -, Option: -
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: -
(If not specifying dimension C2, indicate "" instead.) C1 = C (mm) (mm) Size Size L1 max. L2 max.
Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet y Connection C2 thread N S U F GN GS B3 M3 x 0.5 3 11 6 6 10 15 25 ZP T 10 13 16 UT Vacuum inlet: One-touch fitting J K A8 Applicable tubing O.D. J B5 M5 x 0.8 5 13 8 Width across flats H Dimensions Per Vacuum Inlet: One-touch Fitting G Model G H J Fitting part min. hole size Vacuum inlet direction q Pad dia.
Fittings & Tubing Air Cylinders Rotary Actuators C2 2 x P (Rc, NPT, G) M5 x 0.8 Effective thread length 2 x FL Width across flats B2 2 x NN B (This drawing shows the cases of 20 and 25.)
MM Relief port FX 20, 25 Eh8 D FZ I 20 to 32 Standard port Relief port Width across flats NA 4-FD 45 1.5 AL 32, 40 A F N K N S + Stroke FT H FY Z + Stroke ZZ + Stroke 40 (mm) 4 7 FD E 20-0.033 0 52 40 40 34 B FX FZ FY G FT 13 8 AL D K MM NA NN B1 B2 Bore size ZZ Z H H2 H1 S P N I F C2 A 66 60 60 60 75 75 75 11 8 8 8 40 32 25 20 24 22 22 18 50 45 45 41 8 8 8 6 6 5 22 17 17 13 41 32 32 26