SMC Corporation of America
Elite Part Number Search
Search Results "PSE541A-N01-C2"

ZB-OM00201-B (10) Vacuum (V) port Note10) Note 11) C2 Straight type2 One-touch tube fitting Metric size C4 Straight type 4 One-touch tube fitting N1 Straight type 1/8 One-touch tube fitting Inch size N3 Straight type 5/32 One-touch tube fitting L2 Elbow type 2 One-touch tube fitting Metric size L4 Elbow type 4 One-touch tube fitting LN1 Elbow type 1/8 One-touch tube fitting Inch size

www.stevenengineering.com I 1.224 GRIPPERS AIR CHUCKS SERIES MH D I M E N S I O N S A N G U L A R T Y P E MHC2-20D/S H O W T O O R D E R S E R I E S MHQ/MHQC A I R C H U C K S MH F U N C T I O N Q2 Parallel C2 Angular D I M E N S I O N S A N G U L A R T Y P E MHC2-25D/S B O R E S I Z E 10 10mm 16 16mm 20 20mm 25 25mm A C T I O N D Double S Single (Normally Open) C Single (Normally Closed)

: Moment center position distance compensation amount My L1 A2 L3 C2 (mm) B2: Moment center position distance compensation amount MXW8 MXW12 MXW16 MXW20 MXW25 23 29 37 49 63 A2: Moment center position distance compensation amount Mr (mm) (mm) W Mp MXW8 MXW12 MXW16 MXW20 MXW25 39 48 58 75 97 MXW8 MXW12 MXW16 MXW20 MXW25 10 10 14 20 28 W W 8-7-2 3 Long Stroke Slide Table Series MXW Dynamic

Number of connecting tubes Accessory (Option) How to Use 6 12 Nil C1 C2 None Cover single side 1 pc. Cover both sides 2 pcs. 6 12 Caution K Disassembly (1) Loosen clamp ring and disassemble the connector into the plug case and socket case. Style Tubing O.D.

Number of connecting tubes Accessory (Option) How to Use 6 12 Nil C1 C2 None Cover single side 1 pc. Cover both sides 2 pcs. 6 12 Caution K Disassembly (1) Loosen clamp ring and disassemble the connector into the plug case and socket case. Style Tubing O.D.

CS1 CS2 34 + Stroke 14 2.5 17.5 + Stroke 4.5 4.5 7 7 Mounting nut Width across flats 10 6 2 x M3 x 0.5 6 7 Width across flats 4 Rod end nut 1.7 2 14.5 5 30 C2 M2 x 0.4 Without rod end thread M8 x 1.0 3 14 D-X Individual -X Technical data 27 Series CJP2 Dimensions: Basic Mounting (6 to 16) Standard: CJP2B6 to 16 Z + Stroke H S + Stroke A' F GB GA 2 x P A F' Mounting nut Width across flats

: Moment center position distance compensation amount (mm) L1 A2 My L3 C2 A2: Moment center position distance compensation amount (mm) B2: Moment center position distance compensation amount (mm) MXW8 MXW12 MXW16 MXW20 MXW25 23 29 37 49 63 Mr W MXW8 MXW12 MXW16 MXW20 MXW25 39 48 58 75 97 Mp MXW8 MXW12 MXW16 MXW20 MXW25 10 10 14 20 28 W W 148 Series MXW Air Slide Table Dynamic Moment Moment

-1.8WDC WF333O Exhaust Conter NVF343O GNced Center (B) (A) (B) (a) 01 c2 \ t \ T I'f E I J E Z (R2)(PxFl) (R2XPXR1) Prssure Center NVF3530 (B) (A) Spej;ifications -, Flurd-Art f Operatangprssurcrange2Positionsingle2O-12gPSlS(1.5-9kgF) U 2 pooition double-1 5 1 28 PSI (1 9kgf/cm'?

A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits

A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits

Number of connecting tubes Accessory (Option) How to Use 6 12 Nil C1 C2 None Cover single side 1 pc. Cover both sides 2 pcs. 6 12 Caution K Disassembly (1) Loosen clamp ring and disassemble the connector into the plug case and socket case. Style Tubing O.D.

5000 Rc G NPT NPTF Pilot type Nil R A, B port size Thread piping Symbol Port size M5 01 Except M5 Internal pilot External pilot Option for mounting Nil 1 Applicable series SY3000 SY5000 M5 x 0.8 1/8 Standard (Valve mounting screw not falling-out-prevention type) Valve mounting screw falling-out-prevention type One-touch fitting (Metric) Applicable series SY3000 SY5000 Port size Symbol C2

C1: With connector cable (Length 300 mm) C2: With connector cable (Length 600 mm) C3: With connector cable (Length 1000 mm) Note) The applicable tube of the barb fitting shows the tube outside diameter/inside diameter.

Cable type 5, 6, 7 Cable length [m] 5, 8 Driver type 5 I/O connector Nil Nil Power supply voltage (V) Compatible drivers Nil Without connector Without cable Without cable H S R 2 5 With connector Nil Without driver Standard cable 2 m 5 m A1 A2 B1 B2 C1 C2 S1 S2 LECSA1-S; LECSA2-S; LECSB1-S; LECSB2-S; LECSC1-S; LECSC2-S; LECSS1-S; LECSS2-S; 100 to 120 200 to 230 100 to 120 200 to 230 100

LECSB2/Pulse input type B2 200 V to 230 V (Absolute encoder) Motor option LECSC2/CC-Link C2 200 V to 230 V Nil Without lock (Absolute encoder) B With lock LECSS2/SSCNET III S2 200 V to 230 V (Absolute encoder) Motor type Type Output Actuator Compatible Symbol [W] size drivers Mounting 1 AC servo motor Symbol Motor mounting position Type In-line S4 400 63 LECSA2-S4 (Incremental encoder) LECSB2

MY2H G D Za MY3A MY3B 4 x MM E1 E1 MY3M E4 E4 E3 E3 C E2 E2 F B G D Section Za detail (Adjustable range) Section Z detail (Adjustable range) Q P Zb JJ F B3 K B2 H B1 C1 Z B F A L 2 x 2 x LD Section Zb detail (Adjustable range) H A H A holding bolt (mm) B C D F G 90 H A Model MY-J50 MY-J63 Applicable bore size MY1B50 MY1B63 110 110 55 70 126 37 J C2 C 131 130 65 80 149 100 37 K L P Q E3 E4

Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 6 (12VDC), Coil Specifications: Standard (w/Light Surge Voltage Suppressor)(+COM), Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C2 (Length 600mm)

Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 6 (12VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C2 (Length 600mm), Bracket: F (With Bracket)

Valve Stations: 04 (4 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 6 (12VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C2 (Length 600mm), Bracket: F (With Bracket)

Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 5 (24VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C2 (Length 600mm), Bracket: F (With Bracket)