5 Port Air Operated Valve Series SYA3000/5000/7000 How to Order One-touch fitting (Inch size) A, B port size Thread type Thread piping Rc Nil Symbol Port size Applicable series M5 01 02 Symbol Port size Applicable series N3 N7 N3 N7 N9 N9 N11 G F 5 32" SYA3000 SYA5000 SYA7000 M5 x 0.8 One-touch fitting for N NPT SYA3000 1 8 1 4 Except for M5 1 4" One-touch fitting for NPTF T 5 32" One-touch

Type 40/Type 41 How to Order SS3YJ7 40 05 01 Applicable solenoid valve SYJ714SYJ714MSYJ724SYJ724MApplicable blanking plate assembly SYJ700-10-2A R port 1/4 R port 1/8 P, R port thread type Manifold type Stations 40 41 Type 40 Type 41 Nil Rc G NPT NPTF 2 stations : 20 stations 02 : 20 A A F N T A A 01 1/8 A port size P port 1/8 P port 1/4 A port 1/8 A port 1/8 Note) If there are more than

(SD0) Without input block With 1 input block 0 1 Ports 2, 4 size (inch) Ports 2, 4 Symbol N7 N9 N11 NM Ports 1, 3, 5 1/4" One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting Mixed 8 With 8 input blocks 1: 1/2 3, 5: 3/4 Note) When an AS-i compatible S kit is used, there is a limit on the maximum number of stations.

Select between two values 2-A or 1-A using the + and keys. The value 2-A indicates a double acting actuator and 1-A a single acting actuator. To conclude press the ?

A port N.O. (A)4 2(B) (A)4 2(B) Locked position Number of solenoids Single 1 (P) (EA)5 3(EB) 1 (P) (EA)5 3(EB) LOCK 2(B) (A)4 2(B) (A)4 Double PUSH (EA)5 1 (P) 3(EB) (EA)5 1 (P) 3(EB) Caution How to Use Plug Connector When operating the locking type D with a screwdriver, turn it gently using a watchmakers screwdriver. [Torque: Less than 0.074 lbfft (0.1 Nm)] Caution 1.

VQ4 VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Connector wiring diagram (mixed wiring) VQZ 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 VQD 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2

1 (P) (A) 4 (B) 2 3 position exhaust center (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 i 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) (This figure shows a closed center type.)

CFM x 10-2 1 CFM x 10-2 Accumulated Setting/Display flow range 0.0 to 9.0 0.0 to 9.9 0 to 9 0 to 9 ft3 x 10-1 ft3 x 10-1 ft3 x 10-1 ft3 x 10-1 flow Min. setting/display unit 0.1 ft3 x 10-1 0.1 ft3 x 10-1 1 ft3 x 10-1 1 ft3 x 10-1 Conversion of accumulated pulse 0.1 1 1 1 ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse : Flow rate in the specification is the value at standard

Contents Bore size (mm) Seal Kit List Description Material Note No. 16 20 25 32 40 50 63 80 100 MGP16-A-PS MGP20-A-PS MGP25-A-PS MGP32-A-PS MGP40-A-PS MGP50-A-PS MGP63-A-PS MGP80-A-PS MGP100-A-PS @6 @7 @8 @9 #0 #1 Piston seal NBR Rod seal NBR Cushion seal Urethane Set of left nos. @6, @7, @8, @9, #0, #1 Gasket A NBR Gasket B NBR Gasket C NBR Seal kit includes @6 to #1.

Sl unit output No. 0 1 2 3 4 5 6 7 8 9 A B A B A Void A Void A B A B A B B A A A SY Double Double Double Double Double Sl unit Sl unit Single Single Single Single Single SYJ Stations Stations 1 2 3 4 5 1 2 3 4 5 Double wiring (Standard) Single/Double mixed wiring (Option) SX VK SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link System (Sharp) VZ ADDRESS NO.

(A) 4 (A) 4 (B) 2 (B) 2 (Example) SS5YJA7-41-03-01 1 pc. SYJA7140 1 pc. SYJA7240 1 pc. SYJ7000-21-1A 1 pc. 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 position exhaust center 3 position closed center (A) 4 (A) 4 (B) 2 (B) 2 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) The asterisk denotes the symbol for assembly.

(A) 2 (A) 2 2(A) 2(A) 3(R) (P)1 3(R) (P)1 i i 3 (R) 1 (P) 3 (R) 1 (P) u u Component Parts Replacement Parts Description Body Piston plate End cover Piston Spool valve assembly Spool spring No. No. 1 2 3 4 5 6 Description Note White White White Note Part no.

(Looked by double solenoid valve) (Looked by double solenoid valve) SOL. location B (*) B (*) B B A B A B A B A B A A A A B A B A SOL. location VQC 3 position 3 position Double Double Double Double SI unit Single Single SI unit Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 VQ0 The places of asterisk are not used.

A Qty. 1 136019 A O-ring 136019 NBR B Fitting assembly See below 1 The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series ARM5A.

A Qty. 1 136019 A O-ring 136019 NBR B Fitting assembly See below 1 The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series ARM5A.

KJH01-C1 1/8" one-touch fitting (Straight) 2a, 2b KJH03-C1 5/32" one-touch fitting (Straight) 13 VVQ1000-50A-N3 5/32" one-touch fitting (Straight) 1(P), 3(E) VVQ1000-50A-N7 1/4" one-touch fitting (Straight) 3 3 Port Solenoid Valve Series VV100/D-sub Connector Plug-in Connector Type Manifold How to Order Manifold U 1 VV100 10F C6 05 D A 2 D-sub connector type Mounting option Symbol A B Number

B 1 0 A B 1 0 A B 1 0 A B 1 0 9 61.5 A A A A R4.5 26 62.5 97 = 4.5 (5.5) (35) (L3) (5.2) 52 (L4) Stations D side U side 1 2 3 4 5 6 7 8 n 2-C6 P(SUP) port P A P A A A A A A A 24.5 (11) 13.5 R B R B B B B B B B (7.5) 7 2-C6 R(EXH) port 19.2 P = 11 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 threads Broken lines indicate DIN

A port 1/8 Type 42 How to Order SS3YJ7--42-05 -C6 Applicable solenoid valve SYJ714SYJ714MSYJ724SYJ724MApplicable blanking plate assembly SYJ700-10-2A Stations R port 1/4 P, R port thread type A port size -+ -+ -+ -+ 02 : 20 2 stations : 20 stations 01 C6 C8 N7 N9 1/8 P port 1/4 A A Nil Rc G NPT NPTF R X 6 one-touch fitting P F N T 8 one-touch fitting A port 1/8 1/4" one-touch fitting 5/16

Common (+, ) Station 1 A side Station 1 B side Station 2 A side Station 2 B side Station 3 A side Substrate for single Station 3 Substrate for double Station 2 Substrate for double Station 1 A and B ports can be individually controlled. Three combinations are available: [N.C./N.C.], [N.O./N.O.] and [N.C./N.O.].