Bore: 16, Body: Standard, Stroke: 40mm, Adjuster/Functional Option: ZT (Shorter Overall Length, Metal Stopper, Retraction), Functional Option: w/o Functional Option, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connection: L (3m)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]

Structure: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): None

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F02 (G1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

Structure: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

Structure: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: G1/4, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

35 + 25 (n 2) (n = 2, 3, 4, 5) CJ2 D-A9lV 5 10 35 10 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 25 (n 2) (n = 2, 3, 4, 5) CM2 Band mounting CG1 D-H7l/H7lW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) MB D-C7l D-C80 10 15 50 15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) CA2 D-H7C D-C73C D-C80C 10 15 65 15 + 50(n 2)

A, B, EA, EB port) Nil R External pilot Internal pilot 1 4 3 8 02 03 Plug-in VFR3000 P 02 Thread type Non plug-in VFS3000 S 02 Nil F G Rc N NPT NPTF T B Plug-in VFR3000 P 02 Non plug-in VFS3000 S 02 B Piping port (P, A, B, EA, EB port) Note) Mounting bolts and gaskets are not attached. 1 4 02 3-5-31 32 Series VFR3000 Construction 2 position single 2 position

Series VC 2 3 4 Class 2 Class 3 Class 4 OUT port size VDW Port size 1/8 (6A) Symbol 01 02 Stations Uside D side 1/4 (8A) Material VQ Stations 1 2 3 4 5 n 02 2 stations All IN ports are 3/8.

(24 VDC) 02 2 stations Rc Nil 3 SY3000 5 SY5000 SY3240-5G(-Q) (2 sets) 3 2 1 Stations ... ...

2 121 106 L L1 L2 S070 With mounting adaptor: VV317-02-1-02-A VQ 4-7 mounting hole P = 46 VKF VQZ VZ Manual override (Non-locking) VS DIN terminal facing upward 141.6 VFN Applicable cable O.D. 6 to 12 L Dimension n: Stations Stations Formula L1 = 46 x n + 89 L2 = 46 x n + 59 2 181 151 3 227 197 4 273 243 5 319 289 6 365 335 7 411 381 8 457 427 9 503 473 10 549 519 L L1 L2 4-7-15 16 Series