: L plug connector, Without lead wire LO: L plug connector, Without connector 5 24 VDC 6 12 VDC 9 Other Option D: DIN terminal M: M plug connector, With lead wire MN: M plug connector, Without lead wire H: Grommet, Lead wire length 600 mm MO: M plug connector, Without connector DO: DIN terminal, Without connector Type G, L and M: Lead wire 300 mm 4-15-2 3 3 Port Solenoid Valve Metal Seal
Nil M MB Note 1) For the double solenoid specification, the symbol for Function is "D". Note 2) Only rubber seal types are applicable.
Type LN, MN: With 2 sockets. 3-3-17 Series VZ3000 Specifications Applicable for cylinder actuation (up to 40).
Tgpe 40 Manifold,/ Side Ported inch (mm) Grommet (G), (H) Lead wire length L typ plug connector (L) M type plug connctor (M) Type 40R Manifold,/ Side Ported(External Pilot) inch (mm) Grommet (G), (H) L type plug connector (L) M type plug connector (M) inch (mm) crommet (G), (H) 4O Manifold,/ Bottom Ported (ln case oa to-32No.n.
Electrical entry 24, 12, 6, 5, 3 VDC Grommet L plug connector M plug connector G: Lead wire length 300 mm H: Lead wire length 600 mm L: With lead wire (Length: 300 mm) LN: Without lead wire LO: Without connector M: With lead wire (Length: 300 mm) MN: Without lead wire MO: Without connector * LN and MN types are with 2 sockets. * Refer to page 1737 for the different lead wire lengths of L
VDC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P E: Push-turn locking lever type B: Locking slotted type H: 600 mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 4632 LN and MN types
VDC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P E: Push-turn locking lever type B: Locking slotted type H: 600 mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 4632 LN and MN types
Max.allowable load W max. : Table 2 1=W/Wa 3-2 Load rate of static moment M=W(Ln+An)/1000 Corrected value for center position distance of moment An : Table 3 Ma=M max. Allowable moment coefficient : Graph 2 Max.allowable moment M max. : Table 4 Calculate static moment M(Nm). Examine for Mr [As Mp and My does not arise, Examination is not needed.]
5V, 3V DC Grommet L plug connector M plug connector : Non-locking push style D: Push-locking slotted style G: 300mm lead wire L: 300mm lead wire M: 300mm lead wire MN: Without lead wire L P E: Push-locking lever style B: Locking slotted style H: 600mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 0 LN or MN option includes 2 sockets.
vr'hen 3 pos to. manifold a lalves m!
(Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
plug connector For DC For AC G: 300 mm lead wire L: 300 mm lead wire M: 300 mm lead wire MN: Without lead wire H: 600 mm lead wire ++ ++ LN: Without lead wire LO: Without connector MO:Without connector + LN and MN types are with 2 sockets. 4-2-5 6 Series V100 Base Mounted (With sub-plate) Note) [ ]: values for large flow type (A).
VDC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P E: Push-turn locking lever type B: Locking slotted type H: 600 mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 4632 LN and MN types
entry Nil R U Without light/surge voltage suppressor With surge voltage suppresser With light/surge voltage suppresser For DC 24, 12, 6, 5, 3 VDC Grommet L plug connector M plug connector L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire G: Lead wire Length 300 mm H: Lead wire Length 600 mm ++ ++ LN: Without lead wire LO: Without connector MO: Without
(ln the case of O COM external power supply) (ln the case oJ O COM external power supply) (ln ihe case of O COM external power supply) Connection Examples to Relay and Solenoid Valve 2 wire system relay load 3 wire system solenoid valve load Compact Guide Cylinder: Series MGQ Contact Protection Box D-Zl type ahd D-28 type switches have no built-in cdrkct protection circuit.
PU-10M-RRD Silencers/Exhaust Cleaner Series AN/Series AMC Series Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting Series AN00 100 m 150 m Page 5-10-2 30 dB (A) Compact type Space-saving compact type Series AN03 100 m 25 dB (A) Page 5-10-3 Metal case type Exhaust in only one direction.
Nil Air operated Nil Note) Air operated 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC ( Hz) 110 VAC ( Hz) Filter specifications (F) L LN Lead wire length 0.3 m L plug connector type 5 6 V S R Nil No setting Without lead wire Unit specifications LO Without connector M Lead wire length 0.3 m Digital pressure switch for vacuum (ZSE30A) specifications (D) M plug connector type Nil M P With unit switching
Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer AS2051F-06 AN120-M5 AS3001F-06 AN110-01 SY3120-C6 SY3140-01 T0604 x 1 m T0806 x 1 m AS3001F-06 T0604 x 1 m T0806 x 1 m AS3001F-08 AS3001F-06 SY5120-01 SY5140-02 AS3001F-08 AN101-01 AN101-01 T1075 x 1 m T0604 x 1 m T0604 x 1 m T1209 x 1 m T1075