Magnet: None, Mounting: Both Ends Tapped, Bore Size: 63mm, Stroke 1: 5mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Low Speed Cylinder
Magnet: Built-in Magnet, Mounting: Rod Flange, Bore Size: 100mm, Stroke 1: 5mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Low Speed
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 20mm, Stroke 1: 5mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Low Speed
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 63mm, Stroke: 50mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Resistant: XB14 [w/Heat Resistant Auto
Magnet: D (Built-in Magnet), Mounting: B (Standard, Through-hole), Bore Size: 63mm, Stroke 1: 5mm, +: None, Stroke 2: 0, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke
Magnet: D (Built-in Magnet), Mounting: B (Standard, Through-hole), Bore Size: 63mm, Stroke 1: 5mm, +: None, Stroke 2: 0, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 63mm, Stroke: 50mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 63mm, Stroke: 50mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC35
Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Stroke: 50mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A90--Reed, AC Volt, Horizontal
Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Stroke: 50mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Stroke: 50mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical
Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Stroke: 50mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: L (3m)