SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, FE, 12MM CQ2-Z DBL-ACT AUTO-SW, .44092 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, GE, 16MM CQ2-Z DBL-ACT AUTO-SW, .37511 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, IE, 25MM CQ2-Z DBL-ACT AUTO-SW, .42461 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 140
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p COMPACT CYLINDER. Compact Cylinder, CQ2-Z. 233.4 lb. 493.
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160
Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V,12 V 3-wire (PNP) M9PV M9P V V V v v Grommet Solid state auto switch 2-wire 12 V M9BV M9B V V V v v Connector H7C
Relay, PLC Grommet Yes 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) M9BV 3 m L (Example) M9NL 5 m Z (Example) M9NZ Auto switches marked with a symbol are produced upon receipt of order.
M9B M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V,12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V,12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 M9PAV1 M9PA1 v v
M9B M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V, 12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 M9PAV1 M9PA1 v
For 10, 16, 20 Lead wire length (m) Auto switch model Pre-wire connector Applicable load Perpendicular In-line Load voltage Indicator light Electrical entry Special function Wiring (Output) Type 0.5 (Nil) 3 (L) 5 (Z) DC AC A96 A93 M9N M9P M9B F9NW F9PW F9BW A96V A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN equivalent) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP)
Auto switch model Load voltage Lead wire length (m) Indicator light (N) Applicable load Pre-wired connector Type Special function Electrical entry Wiring (Output) None 0.5 1 (M) 3 (L) 5 (Z) DC AC Perpendicular In-line (Nil) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9N M9P M9B M9NW M9PW M9BW M9NA IC circuit 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire
AC Lead wire length (m) Load voltage DC Auto switch model Special function Electrical entry Indicator light Wiring (Output) Pre-wired connector Applicable load Type In-line Perpendicular 0.5 (Nil) 1 (M) 3 (L) 5 (Z) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9PAV M9BAV M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Solid state switch 2-wire 3-wire (NPN
Auto switch model Lead wire (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Indicator light Electrical entry Type Special function Perpendicular In-line 0.5 (Nil) 3 (L) 5 (Z) 1 (M) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire IC circuit 5