SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2L10-300-H7C"

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector, 0.5M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 300 (3"), Port Location: R (In-line), Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector, 0.5M

Standard Stroke Table Bore size (mm) 20, 25, 32, 40 Standard stroke (mm) 25, 50, 75, 100, 125, 150, 200, 250, 300 Note 1) Intermediate strokes not listed above are also available. Note 2) As the stroke increases, more sliding resistance may result due to the deflection of the piston rod and other factors.

C76 5V IC circuit Yes B53 PLC B54 12V Reed switch Solid state switch 200V or less Grommet B64 No 12V C73 Yes 100V 2 wire 24V Relay, PLC 5V, 12V C80 No IC circuit 100V or less 12V C73C Yes Connector 5V, 12V C80C No IC circuit 24V or less Diagnostic indication (2 color indicator) Grommet B59W Yes 3 wire (NPN) H7A1 G59 IC circuit 5V, 12V 3 wire (PNP) H7A2 G5P Grommet H7B K59 2 wire 12V H7C

Old New Old New Output (+) Power supply + Red Brown Red Brown When excessive impact (300 m/s 2 or more) is applied to a reed switch during operation, the contact point may malfunction and generate or cut off a signal momentarily (1ms or less). Please consult with SMC regarding the need to use a solid state switch depending on the environment.

Old New Old New Output (+) Power supply + Red Brown Red Brown When excessive impact (300 m/s 2 or more) is applied to a reed switch during operation, the contact point may malfunction and generate or cut off a signal momentarily (1ms or less). Please consult with SMC regarding the need to use a solid state switch depending on the environment.

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: H7C, Lead Wire Length(m): 5

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: H7C, Lead Wire Length(m): 5

Mount, Non-Rotating Rod Series CJ2RK 6-3-68 Single rod Single acting Single rod, (Spring return/ Spring extend) 6-3-72 With end lock Series CBJ2 Double acting Single rod 16 6-3-77 Type Band mounting style Rail mounting style D-C7/C80, D-C73C/C80C D-A7/A80, D-A7H/A80H, D-A73C/A80C, D-A79W D-F7/J79, D-F7V, D-J79C, D-F7W/J79W, D-F7WV, D-F7BAL, D-F79F , D-F7NTL, D-F7BAVL Reed switch D-H7, D-H7C

Refer to 1 10 p.0-39 to 0-46 for Safety 2(same surface) 65 D-C73C D-C80C D-H7C Instructions and common precautions. ( ) 6 2(different surfaces) 15 10 1 10 Caution 2(same surface) 65 16 Mounting 2 (different surfaces) 25 D-H7LF q During installation, secure the rod cover and tighten by applying an appropriate tightening force to the retaining nut or to the rod cover body.

Lead wire length (m) Load voltage Indicator light Auto switch model Pre-wire connector Applicable load Special function Type Electrical entry Wiring (Output) AC DC 0.5 (Nil) 3 (L) 5 (Z) None (N) C73 C80 B53 B54 B64 C73C C80C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF G59 K59 100 V Yes 12 V Relay, PLC No IC circuit 100 V or less 5 V, 12 V Reed switch Solid state switch Grommet PLC Yes

) Caution D-H7C Auto switch model number Precautions Wiring 2 wire qConfirm that the connector is appropriately tightened.

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C73C--Reed, DC Volt >5 <24, LED, Connector, 0.5M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C73CL--Reed, DC Volt >5 <24, LED, Connector, 3M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C73L--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, 3M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C73L--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, 3M, Number: S (1 pc.)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: H7A1L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 3M

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: H7A1L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 3M, Number: S (1 pc.)