SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2B10-150R-C80"

RB Type Model Features Applicable bore size (mm) J Electrical entry Grommet Connector Grommet Grommet Grommet D-C80 D-C80C D-B53 D-B64 D-G5NTL 20 to 63 Without indicator light DReed switch Without indicator light 20 to 100 With timer -X Solid state switch With pre-wire connector is available for D-G5NTL type, too. Refer to page 10-20-60 for details.

Note) When two D-A93/M9/M9W auto switches are used 1397 Series RSG Operating Range Auto switch model Bore size (mm) 40 50 D-A9 8 8 D-M9 D-M9W 4.5 5 D-C7/C80 D-C73C/C80C 10 10 D-H7/H7W D-H7BAL/H7NF 5 6 D-H7C 10 9.5 Since this is a guideline including hysteresis, not meant to be guaranteed.

BBA3: D-B5,B6,G5,K5 types BBA4: D-C7,C80,H7 types Note 3) Refer to page 1681 for details on the BBA3. The above stainless steel screws are used when a cylinder is shipped with the D-H7BA/G5BA auto switches. When only an auto switch is shipped independently, the BBA3 or BBA4 is attached. MB1 CA2 CS1 CS2 a (1) BJ-1 is a set of a and b.

ML1C 25 Bore size (mm) Auto switch model D20 20 25 32 40 32 20 D-B5/B64 D-G5/K5 BA-01 BA-02 BA-32 BA-04 25 20 -X 10 D-C7/C80 D-H7 BMA2-020 BMA2-025 BMA2-032 BMA2-040 20Mounting screws set made of stainless steel The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

ML1C 25 Bore size (mm) Auto switch model D20 20 25 32 40 32 20 D-B5/B64 D-G5/K5 BA-01 BA-02 BA-32 BA-04 25 20 -X 10 D-C7/C80 D-H7 BMA2-020 BMA2-025 BMA2-032 BMA2-040 20Mounting screws set made of stainless steel The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

Time load applied (ms) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model D-C80). 4. Wiring should be kept as short as possible. 3) Generally, the internal voltage drop will be greater with a 2 wire solid state auto switch than with a reed switch.

-X 585 RSG Series Auto Switch Mounting 2 Operating Range Auto switch model Bore size (mm) 40 50 D-A9(V) 8 8 D-M9(V) D-M9W(V) D-M9A(V) 5 4.5 D-C7/C80 D-C73C/C80C 10 10 D-H7/H7W D-H7BA/H7NF 6 5 D-H7C 9.5 10 Since this is a guideline including hysteresis, not meant to be guaranteed.

IC circuit 5V C76 B53 B54 B64 C73 C80 C73C C80C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA G5NT H7NF H7LF PLC Yes 12V 100V, 200V 200V or less 100V 100V or less 24V or less Grommet No Yes 12V 5V, 12V 12V 5V, 12V 24V 2 wire Relay, PLC No IC circuit Yes Connector No IC circuit Grommet Yes Diagnostic indication (2 color indicator) 3 wire (NPN) 3 wire (PNP) IC circuit 5V, 12V Grommet

CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B

Applicable crimp-style terminal 1.25Y-3L, 1.25-3.5S, 1.25-4M 7-9-39 40 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Band Mounting Style Caution Reed switchD-C73, D-C76, D-C80, D-C73C, D-C80C Solid state switchD-H7A1, D-H7A2, D-H7B, D-H7BAL D-H7C, D-H7NF, D-H7NW, D-H7PW, D-H7BW 1.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Hs 14.5 Auto switch D-B7/B8/G7/K7 Hs 14.5 Auto switch Proper Auto Switch Mounting Position Auto Switch Mounting Height D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-G5/K59 D-G5W D-K59W D-B5/B64 D-B59W D-G5BAL D-G59F D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C Auto

CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B

C76 IC 5V Grommet Yes Reed switch Solid state switch C73 C80 C73C C80C H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF H7LF 12V 100V IC No 5V, 12V 100V or less Relay, PLC 2 wire 24V 12V Yes Connector IC 24V or less 5V, 12V No 3 wire (NPN) IC 5V, 12V Grommet 3 wire (PNP) 2 wire 12V Connector 3 wire (NPN) Yes IC Relay, PLC 24V 5V, 12V Diagnostic indication (2 color, With timer) 3 wire (PNP

(Example) CDNGLN40-100-D 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC 3 wire (NPN equiv.) 5V C76 IC circuit Yes B53 B54 B64 C73 C80 C73C C80C PLC 100V, 200V Solid state switches Reed switches 12V Grommet Mounting brackets part numbers 200V or less No 100V 12V Yes 2 wire 24V Refer to page 3 for the part numbers of mounting brackets for other than the basic air cylinder.

SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available MODEL LEAD WIRE ENTRY APPLICATIONS LOAD VOLTAGE MAX LOAD CURRENT/LOAD CURRENT RANGE NCY2 ACCESSORIES PART NO APPLICABLE DIAMETER D-C73 Grommet PLC 24 VDC 5 ~ 40 mA Rear Clevis Pin NCD-J010 10 110VAC 5 ~ 20 mA NCD-J016 16 D-C76 Grommet PLC 4 ~ 8 VDC 20 mA Double Rod Clevis NY-J010B 10 24V AC/DC or less 50mA NY-J016B 16 D-C80

Minimum operating voltage of load Supply voltage > Internal voltage drop of switch 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, DA80, D-A80H, D-A90, D-A90V, D-B64, D-C80, or D-Z80).

Auto switch model Band mount (16) Indicator light Wiring (output) Electrical entry Applicable load Rail mount Special function Type 5 (Z) None (N) 0.5 (Nil) 3 (L) DC AC Perpendicular In-line 3 wire (NPN) C76 A76H 5V IC circuit Yes A72 A73 A80 A73C A80C A79W F7NV F7PV F7BV J79C F7NWV A72H A73H A80H Grommet 200V Reed switch Solid state switch Rail mount type CDJ2XB10-45-A Example C73 C80

(NPN) Yes/3 Wire (PNP) Yes/2 Wire Yes/4 Wire (NPN) Yes/4 Wire (NPN) Yes/2 Wire No/3 Wire (NPN) Yes/2 Wire D-G59 D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80

C76 IC 5V Grommet Yes Reed switch Solid state switch C73 C80 C73C C80C H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF H7LF 12V 100V IC 5V, 12V 100V or less No Relay, PLC 2 wire 24V 12V Yes Connector IC 24V or less 5V, 12V No 3 wire (NPN) IC 5V, 12V Grommet 3 wire (PNP) 2 wire 12V Connector 3 wire (NPN) Yes IC Relay, PLC 24V 5V, 12V Diagnostic indication (2 colour, With timer) 3 wire (

IC circuit C76 C73 C80 B53 B54 B64 C73C C80C A33 A34 A44 B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW G5NT H7NF 5V Yes 100V 12V Relay, PLC Port on right 3 No 100V or less IC circuit 5V, 12V Grommet PLC 12V Yes Reed switch Solid state switch 100V, 200V 12V 200V or less No Relay, PLC 12V 2 wire 24V Port on top Yes 4 12V Connector 24V or less IC circuit No 5V, 12V PLC 12V Terminal conduit