300 100 MI W S 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 CEP1 Max. 500 mm/s of high speed transfer is possible.

JIS symbol Minimum Operating Pressure Unit: MPa Bore size (mm) Minimum operating pressure 20 25 32 40 50 63 80 100 0.02 0.01 Standard Stroke Table Replacement Parts: Seal Kits Bore size (mm) Bore size (mm) 20 25, 32, 40, 50, 63, 80, 100 Standard stroke (mm) Note 1) Contents Kit No. 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 20 25 32 40 50 63 80 100 CG1Y20-PS CG1Y25

50 100 40 20 R: 0.35, H: 0.42 R: 7, H: 7.5 25 R: 0.56, H: 0.65 R: 7, H: 7.5 100 32 Total load weight (kg) 32 0.91 7.5 100 25 40 1.8 8.7 10 50 3.4 11.8 100 20 High kinetic energy generated by large loads and high speed operations can be absorbed by compressing air at the stroke end thus preventing shock and vibration being transmitted to the machine.

Lead wire (m) Load voltage Indicator light Pre-wire connector Wiring (Output) Special function Type Electrical entry Data Applicable load Auto switch model 3 (L) 5 (Z) None (N) 0.5 (Nil) AC DC 3-wire (NPN equivalent) IC circuit C76 5 V Reed switch Solid state switch Grommet B54 C73 C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF 100 V, 200 V 100 V 12 V Yes Yes Relay, PLC 24 V 2-

Roller Type/Round Bar Type/ Chamfered Type Graph (1) Lever Type (With shock absorber) Friction coefficient = 0 Graph (2) Lever Type (With shock absorber) Friction coefficient = 0.1 Graph (3) 100 200 200 50 130 130 50 50 100 100 50 40 40 40 40 Example 1 30 40 50 40 50 Weight of transferred object m (kg) Weight of transferred object m (kg) Weight of transferred object m (kg) 20 30 30 Example

For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet (B59W) G79 Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP) IC circuit

For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet (B59W) G79 Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP) IC circuit

Lead wire length (m) Indicator light Load voltage Wiring (Output) Special function Type Electrical entry Pre-wire connector Auto switch model Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC 3-wire (NPN equivalent) IC circuit C76 5 V Reed switch Solid state switch Grommet B54 C73 C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF 100 V, 200 V 100 V 12 V Yes Relay, PLC 24 V 2-wire

+ 100 (n 2) 35 + 30 (n 2) 10 35 100 Note) For cylinders with two D-A93/M9/M9W auto switches.

+ 100 (n 2) 35 + 30 (n 2) 10 35 100 Note) For cylinders with two D-A93/M9/M9W auto switches.

+ 100 (n 2) 35 + 30 (n 2) 10 35 100 Note) For cylinders with two D-A93/M9/M9W auto switches.

, 125, 150, 200 44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 25 38 80 60 MGP 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 32 46 95 70 75, 100 125, 150 200, 250 300 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 32 50 105 80 MGQ 70 40 160 37 M8 165 85 12 9 125 110 176 160 16 18 107 38 60 125 95 45 194 42 M10 200 95 12 11 135 115 210 190 82.5 19 23 142 50 75 150 115 MGG Bore

Both directions Lock direction MXW MXP Stroke Bearing Standard stroke (mm) Long stroke (mm) Bore size (mm) MG Model MGP 20 75, 100, 125, 150, 200 250, 300, 350, 400 MLGCM Slide bearing 25 350, 400, 450, 500 MGQ 75, 100, 125, 150, 32 350, 400, 450, 500, 600 MLGCL Ball bushing bearing 200, 250, 300 40 350, 400, 450, 500, 600, 700, 800 MGG * Middle strokes and short strokes other than shown

CVS1K 40, 50 63, 80 100 J Standard 10-15-67 Double acting DNonrotating rod 40, 50 63 10-15-78 -X Series MVGQ 2012, 16 20, 25 32, 40 50, 63 80, 100 Data 10-16-1 Double acting 10-15-1 Series CV Valve Mounted Cylinder Precautions Be sure to read before handling.

CVS1K 40, 50 63, 80 100 J Standard 10-15-67 Double acting DNonrotating rod 40, 50 63 10-15-78 -X Series MVGQ 2012, 16 20, 25 32, 40 50, 63 80, 100 Data 10-16-1 Double acting 10-15-1 Series CV Valve Mounted Cylinder Precautions Be sure to read before handling.

Lead wire length (m) Load voltage Indicator light CV Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 3 (L) 5 (Z) None (N) 0.5 (Nil) AC DC MVGQ 3-wire (NPN equivalent) 5 V IC circuit C76 Reed switch Solid state switch Grommet CC Yes Yes C73 100 V 12 V Relay, PLC 2-wire 24 V Connector RB C73C H7A1 H7A2 H7B H7C H7NW H7PW H7BW

Fine Lock Cylinder Double Acting, Single Rod Series CLG1 20, 25, 32, 40 How to Order CL Without auto switch CLG1 100 L E N 25 CL1 MLGC CDLG1 With auto switch H7BW 100 L E N 25 CNG Built-in magnet Number of auto switches MNB 2 pcs. 1 pc. n pcs.

Round Type Low Pressure Hydraulic Cylinder Series CHM 20, 25, 32, 40 3.5MPa How to Order CHM 25 100 L L With Auto Switch CHDM 25 100 C73 With auto switch (built-in magnet) Number of auto switches Nil S n 2 pcs. 1 pc. "n" pcs.

For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet G79 (B59W) Diagnostic indication (2-color indication) IC circuit 3-wire (NPN) 3-wire (PNP) 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V IC circuit 3-wire (NPN) 3-wire (PNP)

Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.