Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are applicable auto switches other than listed, refer to page 413 for details. For details about auto switches with pre-wired connector, refer to pages 474 and 475. D-A9, M9, M9W, M9A auto switches are shipped together (not assembled).

The D-A9 model cannot be mounted on 50. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For 32 to 100, there are applicable auto switches other than listed. Refer to page 273 for details. For details about auto switches with pre-wired connector, refer to pages 474 and 475.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Solid state auto switches marked are produced upon receipt of order. Since there are applicable auto switches other than listed, refer to page 258 for details.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Besides the models in the above table, there are some other auto switches that are applicable.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 23 for details. For details about auto switches with pre-wired connector, refer to the Best Pneumatics No. 3. For the D-P3DWA, refer to the WEB catalog.

switch 2-wire 12 V Relay, PLC Grommet Yes 24 V 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 12 V Yes No Yes No 100 V Reed auto switch Relay, PLC IC circuit 100 V or less Grommet 24 V 2-wire 12 V 100 V, 200 V 200 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ

Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Since there are applicable auto switches other than those listed above, refer to page 42 for details.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to pages 837 and 838 for the details of solid state auto switch with pre-wired connector.

(No freezing of the fluid) Note 2) ANR indicates the flow rate converted to the value at 20C, under the atmospheric pressure and the state of relative humidity 65%.

) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note 4) (C) 0.1 Pump capacity Note 5) (50/60 Hz) (MPa) 0.45/0.65 (at 20 l/min) 0.45/0.65 (at

The minimum bending radius indicates the value, at which the tubing gets bended at the temperature of 20C.

Note) Not applicable with the cases of standard dew point 20C (Nil), 15C (symbol H).

The minimum bending radius indicates the value, at which the tubing gets bended at the temperature of 20C.

E.g.: TEMP SP value: +20C, OFFSET value: +2C Circulating fluid discharge temp.: +20C, TEMP PV: +20C When OFF is selected If no mode is selected, temperature control is conducted to allow the discharge temperature of the circulating fluid to be TEMP SP value.

V After 15 min, cool 32C down to 20C.

Port size Thread type Symbol Bore Size Nil N F Rc NPT G 1 5 10 20 30 3 50 60 75 100 01 1/8 02 1/4 04 1/2 03 3/8 Standard Specifications/Single Style (Standard Dew Point 20C [4F]) Standard dew point 20C (4F) Model IDG1 IDG5 IDG10 IDG20 IDG30 IDG50 IDG60 IDG75 IDG100 IDG3 IDG1 Fluid Compressed air Range of operating conditions Standard performance conditions Standard performance Inlet air

Note) Not applicable with the cases of standard dew point 20C (Nil), 15C (symbol H).

of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C. * This is the calculated value by changing the fluid temperature only.

Metric sizes 6 8 10 12 ASS Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 ASR (free) flow Effective area mm2 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.