Note 3) The value at ambient temperature of 68F (20C) and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Note 1) Apparent power: The value at ambient temperature of 68F (20C) and when the rated voltage is applied.
Fixed end At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%. Max.
Low temperature operation 1) The valve can be used in an ambient temperature of between 10 to 20C.
M km, 20C 5m VVZS3000-21A-3 x 24AWG * For other commercial connectors, use a 25-pole female connector made in conformity with MIL-C-24308.
Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.
in the users equipment: 25 kW Power supply: 200 V 60 Hz Circulating fluid flow: 125 L/min@0.5 MPa External piping: Bypass piping + Heat load 21 Conditions 20 19 25 kW load Heat load fluctuation (0 kW 25 kW) 0 kW load 0 10 20 30 40 50 Time [Minute] Applicable to an ambient temperature of 20C.
(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.
) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note 4) (C) 0.1 Pump capacity Note 5) (50/60 Hz) (MPa) 0.45/0.65 (at 20 l/min) 0.45/0.65 (at
Safety standards CE marking, UL (NRTL) standards *1 Conditions: Circulating fluid set temperature 20C, Flow rate 3 L/min, Facility water temperature 20C, Flow rate 10 L/min, Ambient temperature 25C *2 The indicated values are with a stable load without turbulence in the operating conditions.
E.g.: TEMP SP value: +20C, OFFSET value: +2C Circulating fluid discharge temp.: +20C, TEMP PV: +20C When OFF is selected If no mode is selected, temperature control is conducted to allow the discharge temperature of the circulating fluid to be TEMP SP value.
After 15 minutes, cool 32C down to 20C.
Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa 2 mounting types Ambient and fluid temperature Without auto switch: 20C to 80C (No freezing) With auto switch: 10C to 60C (No freezing) Front side mounting and bottom side mounting available to suit your applications.
Station 11 SOL.B 17 16 22 25 24 Item Property 13 3 SOL.A 23 18 23 Station 12 Conductor resistance W/km, 20C 65 or less SOL.B 12 4 24 26 19 22 COM. 11 5 25 21 20 Voltage limit V, 1 minute, AC 1000 COM. 26 10 9 8 7 6 M27 Female thread Insulation resistance MW/km, 20C 5 or more Note) The minimum bending radius of the multiple connector cable is 20 mm.
20C (68F) bend the tubing into a U shape.
Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.
Symbol Nil 10 mm Coating color White 1 Mass lbs (kg) 119 (54) 137 (62) 258 (117) 271 (123) Compliant standards UL, CSA Note 1) ANR is under the conditions of 68F (20C) at atmospheric pressure and relative humidity of 65%. Note 2) Air flow capacity for each outlet air pressure dew point is indicated. Note 3) Install a circuit breaker with a sensitivity of 30 mA.
EX510 Conductor resistance W/km, 20C 65 or less COM. COM. Manifold Exploded View 13 (+) 13 () Voltage limit V, 1 minute, AC 1000 common Negative common Positive Fitting, Plug Part Nos. Insulation resistance MW/km, 20C 5 or more * When using a valve with no polarity, either positive common or negative common can be used.
65 65 Vertical 145 175 175 Standby power consumption when operating [W] Note 10) Horizontal 2 2 2 Vertical 8 8 8 Electric specications Max. instantaneous power consumption [W] Note 11) 445 724 724 Type Note 12) Non-magnetizing lock Holding force lbf [N] 29 [131] 57 [255] 109 [485] 35 [157] 69 [308] 132 [588] 44 [197] 87 [385] 165 [736] Lock unit specications Power consumption [W] at 68F (20C
of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C.
O When the ambient temperature is 20C 5C and rated voltage is applied. P Coil change from AC to DC or DC to AC is impossible because the iron core shapes are different.