SMC Corporation of America
Elite Part Number Search
Search Results "MXJ8-20C-A93"

(mm) Applicable cylinder bore size (mm) 6, 10, 16, 20 20, 25, 32 20, 25, 32, 40 40, 50, 63 63, 80, 100 Release button color: Light gray 4 6 8 10 12 AS121FP-M5 AS221FP-01 AS221FP-02 AS321FP-03 AS421FP-04 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 Specifications Air Grade 1 (1) Fluid Particulate generation grade Proof pressure (20C) Maximum operating pressure (20C) Minimum operating pressure Ambient

Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa (145 psi) Note 3) Max operating pressure 20C (68F) 100kPa (-14.5 psi) Operating vacuum pressure Caution 3MPa (435 psi) Proof pressure 20C (68F) 20C to 80C (-4 to 176F) Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blow

Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa (145 psi) Note 3) Max operating pressure 20C (68F) 100kPa (-14.5 psi) Operating vacuum pressure Caution 3MPa (435 psi) Proof pressure 20C (68F) 20C to 80C (-4 to 176F) Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blow

Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa Note 3) Maximum operating pressure (20C) 100kPa Operating vacuum pressure Caution 3MPa Proof pressure (20C) 20C to 80C Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blowing and washing lines.

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).

The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure below. Fluid Air/Water Max. operating pressure at 20C 0.8 MPa Burst pressure Refer to the burst pressure characteristics curve. One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Bend the tube into U-form at a temperature of 20C.

Note 3) The value at ambient temperature of 68F (20C) and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Note 1) Apparent power: The value at ambient temperature of 68F (20C) and when the rated voltage is applied.

Fixed end At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%. Max.

Low temperature operation 1) The valve can be used in an ambient temperature of between 10 to 20C.

Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.

in the users equipment: 25 kW Power supply: 200 V 60 Hz Circulating fluid flow: 125 L/min@0.5 MPa External piping: Bypass piping + Heat load 21 Conditions 20 19 25 kW load Heat load fluctuation (0 kW 25 kW) 0 kW load 0 10 20 30 40 50 Time [Minute] Applicable to an ambient temperature of 20C.

(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.

) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note 4) (C) 0.1 Pump capacity Note 5) (50/60 Hz) (MPa) 0.45/0.65 (at 20 l/min) 0.45/0.65 (at

Safety standards CE marking, UL (NRTL) standards *1 Conditions: Circulating fluid set temperature 20C, Flow rate 3 L/min, Facility water temperature 20C, Flow rate 10 L/min, Ambient temperature 25C *2 The indicated values are with a stable load without turbulence in the operating conditions.

E.g.: TEMP SP value: +20C, OFFSET value: +2C Circulating fluid discharge temp.: +20C, TEMP PV: +20C When OFF is selected If no mode is selected, temperature control is conducted to allow the discharge temperature of the circulating fluid to be TEMP SP value.

After 15 minutes, cool 32C down to 20C.

Station 11 SOL.B 17 16 22 25 24 Item Property 13 3 SOL.A 23 18 23 Station 12 Conductor resistance W/km, 20C 65 or less SOL.B 12 4 24 26 19 22 COM. 11 5 25 21 20 Voltage limit V, 1 minute, AC 1000 COM. 26 10 9 8 7 6 M27 Female thread Insulation resistance MW/km, 20C 5 or more Note) The minimum bending radius of the multiple connector cable is 20 mm.

20C (68F) bend the tubing into a U shape.

Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.