(Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.
It takes 10 [ms] to switch the channel. CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.
It takes 10[ms] to switch the channel.
Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms
Available response time settings 1 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms OUT 2 The set-value can be confirmed when the key is locked.
Find the shortest positioning time Tmin [ms] from the graph. Fig.3 Tmin Confirm that the positioning time Tp [ms] is longer than the shortest positioning time.
Air release valve spacer SUP/EXH block disk Double check spacer Throttle valve spacer Dripproof Manifold (Equivalent to IP65) With serial transmission kit Note) Made to Order Specifications 1113 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS1000 Model Model 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) Flow characteristics (1) (2) (3) Max. operating cycle (cpm) Response time (ms
(See Figure on page 59) Switch output NPN or PNP open collector output: 1 output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. applied voltage 28 V (NPN output) Residual voltage 1 V or less (at 80 mA load current) 4 ms or less (with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 10 s, 30 s or 60 s selected) Delay time Short circuit protection Provided
Besides, do not connect a PLC, which can detect 1 [mA], since there is a leak current of 1 [mA] in OFF state. 0 Time Hi 5 to 40 [mA] B 10 [ms] or shorter B 10[ms] or shorter Brown OUT(+) Main circuit of switch Main circuit of switch Load A 5 [ms] or longer 12 to 24 [VDC] When the auto shift input is 10 [ms] or shorter, switch output responds.
Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F5NTL (With indicator light) CRB2 D-F5NTL Auto switch model Wiring type 3-wire CRBU2 Output type NPN Output operation Off-delay CRB1 Operating time 1 ms or less Off-delay time 200 50 ms MSU Applicable load IC circuit, Relay, PLC CRJ Power supply voltage 5, 12, 24
Refer to fault SI unit SI unit MS LED is No.1 OFF malfunction Refer to fault SI unit PWR(V) LED No.2 is OFF Yes No Refer to fault SI unit L/A LED is No.3 OFF Refer to fault SI unit MS LED is No.4 red ON Refer to fault SI unit MS LED is No.5 red flashing Refer to fault SI unit MS LED is No.6 green flashing Refer to fault SI unit MS LED is SI unit NS LED is No.7 green ON OFF Refer to fault
Maximum load current 80 mA Maximum applied voltage (NPN output) 30 VDC Switch output Internal voltage drop (Residual voltage) NPN: 1 V or less (Load current 80 mA) PNP: 1.5 V or less (Load current 80 mA) Delay time 1 1.5 ms or less (delay time available for anti-chattering function: 20, 100, 500, 1000, 2000, 5000 ms) Hysteresis mode Variable from 0 2 Window comparator mode Hysteresis Protection
(reference 25 oC) Switch output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. load voltage 30 VDC (at NPN output) Residual voltage 1 V or less (at load current 80 mA) Output protection Short-circuit protection Output mode Hysteresis mode, window comparator mode Response time 2 ms (10 ms, 50 ms, 0.5 s, 1 s can be selected) Hysteresis Variable Voltage output 1 to
The MS green LED is flashing The MS red LED is flashing Set up configuration correctly. 5.2. PLC setting (Configuration) The MS red LED is on Stop using the product. Contact your sales representative. Does not operate at all.
Refer to fault No.1 SI unit SI unit MS LED is malfunction OFF Refer to fault SI unit PWR(V) LED No.2 is OFF Yes No Refer to fault SI unit L/A LED is No.3 OFF Refer to fault No.4 SI unit MS LED is red ON Refer to fault SI unit MS LED is No.5 red flashing Refer to fault SI unit MS LED is No.6 green flashing Refer to fault No.7 SI unit MS LED is SI unit NS LED is green ON OFF Refer to fault
Response time Life VQZ1000 10 ms 200 million cycles VQZ2000 12 ms VQZ3000 15 ms Built-in One-touch fittings for easier piping. Dispersion accuracy 2 ms Metal seal, single solenoid with light/surge voltage suppressor, according to SMC life test conditions. Integral One-touch fittings save on installation time and labor and can be easily removed if necessary.
1) 15 ms or less 15 ms or less OFF 5 ms or less 5 ms or less PAX Note 1) JIS B 8375 (value of DC voltage specifications at 0.5 MPa supply pressure) (Value of high response time is subject to change upon pressure, quality of air.)
Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 8.4 Controller input signal response Move occasionally Signal timing Check the timing of the signal from the PLC to
With indicator light/surge voltage suppressor Response time ms (at 0.5MPa) Type of actuation Without indicator light/ surge voltage suppressor U types S, Z types 33 or less 38 or less 2 position single 27 or less 28 or less 30 or less 2 position double 50 or less 50 or less 56 or less 3 position 31 or less SY9000 With indicator light/surge voltage suppressor Response time ms (at 0.5MPa)
Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F7NTL (With indicator light) CUJ D-F7NTL Auto switch model Wiring type 3-wire CU Output type NPN Output operation Off-delay CQS Operating time 1 ms or less Off-delay time 200 50 ms CQM Applicable load IC circuit, Relay, PLC CQ2 Power supply voltage 5, 12, 24 VDC