(See Figure on page 59) Switch output NPN or PNP open collector output: 1 output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. applied voltage 28 V (NPN output) Residual voltage 1 V or less (at 80 mA load current) 4 ms or less (with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 10 s, 30 s or 60 s selected) Delay time Short circuit protection Provided

A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.

Note) Auto shift input time Series PSE 200: 10 [ms] or longer Other series: 5 [ms] or longer Hi Auto shift input time Lo Note) Auto shift input time Series PSE 200: 10 [ms] or longer Other series: 5 [ms] or longer 885 Technical Information Auto shift function 12 2-wire pressure switch connections 13 A 3-wire type switch is a switch that has an output line other than the positive and negative

Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

(Station 5) 2 3 Nil 00N 00T 00F VQ20 VQ30 Rc 3/8 NPT 3/8 NPTF 3/8 G 3/8 VQ21M1-5G-C8 1 set Stations VC 01 1 station is the symbol for assembly. Add a in front of the part numbers for solenoid valves, etc., to be mounted.

Measurement mode (Initial setting is completed) Perform the setting with the 3 step setting mode, simple setting mode and function selection mode. -23No.PS-OMW0014-B 3 Step Setting Mode 3 step setting mode In this mode, the set values can be input in just 3 steps. Use this mode if the product is to be used straight away, after changing only the set values.

(Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.

3 SY 3 5 C6 1 0 3 1 Valve Replacement Parts Top ported !

turns Setting trimmer Sensor switch output Red LED lighting Operation indicator light T14 3% FS or less Temperature characteristics 3% FS or less (fixed) Hysteresis 20 to 2,000 ms Timer period 25 mA Max.

www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233 2.75 SOLENOID VALVES SERIES NVFS M O D E L NVFS5000 S Y M B O L S Position Port Size Number Of Type Cv Response (NPTF) 3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 Solenoid Plug-In Factor 4.4 5.4 5.7 4.4 5.4 5.7 3.7 4.6 4.8 3.9 4.8 5 3.9 4.8 4.9 2.2 2.7 2.8

0.0 0.0 0.5 Axis 2 CIR-L 40.00 100 0.0 0.0 0.5 2 Axis 3 0.00 100 0.0 0.0 0.5 Axis 4 20.00 100 0.0 0.0 0.5 Axis 1 CIR-R 100 0.00 1000 1000 100 0.0 0.0 0.5 Axis 2 CIR-R 0.00 100 0.0 0.0 0.5 3 Axis 3 0.00 100 0.0 0.0 0.5 Axis 4 20.00 100 0.0 0.0 0.5 Axis 1 CIR-3 100 0.00 1000 1000 100 0.0 0.0 0.5 Axis 2 CIR-3 -40.00 100 0.0 0.0 0.5 4 Axis 3 -20.00 100 0.0 0.0 0.5 Axis 4 -20.00 100 0.0 0.0 0.5

[F 3] Selection of response time completed : If [.002] is selected during flow indication, actual response time is 3 ms. -30No.PF-OMN0005-E [F 4] External input This function is available when the product includes the external input function : When using a product without external input function, [---] is displayed and this function cannot be set.

Refer to fault No.1 SI unit SI unit MS LED is malfunction OFF Refer to fault SI unit PWR(V) LED No.2 is OFF Yes No Refer to fault SI unit L/A LED is No.3 OFF Refer to fault No.4 SI unit MS LED is red ON Refer to fault SI unit MS LED is No.5 red flashing Refer to fault SI unit MS LED is No.6 green flashing Refer to fault No.7 SI unit MS LED is SI unit NS LED is green ON OFF Refer to fault

It takes 10 [ms] to switch the channel. CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.

1.27 mm 1 2 3 1 2 3 (Normal key) 4 4 4 3 4 3 Connections Socket connector Plug connector pin arrangement A-coded pin arrangement A-coded Min. bending radius 21.7 mm (Fixed) (Normal key) (Normal key) Terminal no.

Refer to fault SI unit SI unit MS LED is No.1 OFF malfunction Refer to fault SI unit PWR(V) LED No.2 is OFF Yes No Refer to fault SI unit L/A LED is No.3 OFF Refer to fault SI unit MS LED is No.4 red ON Refer to fault SI unit MS LED is No.5 red flashing Refer to fault SI unit MS LED is No.6 green flashing Refer to fault SI unit MS LED is SI unit NS LED is No.7 green ON OFF Refer to fault

Product number Description Note ZS-37-A Lead wire with M12 connector Length: 3 m ZS-49-A Lead wire with M12 connector Length: 3 m, M12 (female) M12 (male) -10No.PF-OMX0007-A Names and Functions of Individual Parts Body Connector pin numbers (on the product) 1 DC(+) 2 FUNC 3 DC(-) 4 OUT (C/Q) Element Description Display See below Connector M12 4-pin connector for electrical connections.