Search Results "MGQL63-175-A96"

Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specifications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.

Standard strokes Standard stroke (mm) Long stroke (mm) Bore size (mm) 350, 400, 450, 500, 600 75, 100, 125, 150, 175 40, 50, 63 700, 800, 900, 1000 200, 250, 300 Intermediate strokes and strokes of less than 75mm can also be manufactured.

CQ2 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Built-in Magnet Cylinder Model Double acting Action D 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 RQ If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch. (Example) CDQSL25-30D 25 For Manufacture of Intermediate Strokes, refer to page 552.

Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at

, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80: 1400 100: 1500 Refer to pages 19 to 23 for cylinders with auto switches. 80, 100 Intermediate strokes not listed above are produced upon receipt of order.

Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600

Mass (g) Standard stroke (mm) End lock additional mass Model D25 52 138 186 350 487 918 1,420 5 36 10 40 15 44 20 48 30 56 50 157 222 400 547 1,000 1,533 75 175 258 450 608 1,083 1,645 100 194 294 500 669 1,165 1,758 125 549 729 1,247 1,870 150 599 790 1,330 1,983 175 649 851 1,412 2,095 200 699 912 1,495 2,208 MTS8 MTS12 MTS16 MTS20 MTS25 MTS32 MTS40 29 34 42 55 90 133 -X Bore size (

A96V A96 IC circuit 5 V Yes A72 A93V A90V A73C A80C A79W A72H A93 A90 Grommet 12 V 200 V 100 V RZQ IC circuit IC circuit 5 V, 12 V 12 V 100 V or less No Relay, PLC 2-wire 24V Yes No Connector 5 V, 12 V 24 V or less DGrommet Yes Diagnostic indication (2-color indication) Auto switches marked with a "" symbol are produced upon receipt of order.

Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 25 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 32 to 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Made to Order: Individual Specications (For details, refer to page 491.)

switch Reed switch 3-wire (NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 4-wire (NPN) 3-wire IC circuit Terminal conduit 5 V, 12 V 12 V Relay, PLC Yes IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 24 V 12 V Grommet IC circuit 5 V, 12 V Water resistant (2-color indication) IC circuit 12 V 5 V, 12 V Diagnostic indication (2-color indication) A96

Calculation: (Example) CDM3B40-175 Basic mass of movable parts: Table (2) Rod end [Basic], Bore size [40] 147.3 g Additional mass: Additional mass of stroke 60.6 x 175/50 = 212.1 g 212.1 g Switch magnet 6.0 g OUT 94.2 125.6 314 62.8 157 188.4 219.8 20 8 IN 79.2 105.6 264 52.8 132 158.4 184.8 OUT 147.3 196.4 491 98.2 245.5 294.6 343.7 25 10 IN 123.6 164.8 412 82.4 206 247.2 288.4 OUT

-X1247 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500 600, 700, 800 20, 25 32, 40, 50 63, 80 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500, 600 700, 800, 900,1000 Intermediate strokes and strokes shorter than 75 mm are also available.

Electrical entry Wiring (output) 0.5 (Nil) 3 (L) 5 (Z) Electrical entry direction Applicable load DC Reed switches Solid state switches AC Perpendicular A90V A93V A96V F9NV F9PV F9BV F9NWV F9PWV F9BWV In-line A90 A93 A96 F9N F9P F9B F9NW F9PW F9BW F9BA D-F9 D-F9V D-F9W D-F9WV D-F9BAL Grommet No 5V, 12V 12V 5V IC circuit 100V or less 100V Relay PLC Reed switch Solid state switch 2-wire

Full stroke Note 1) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 Bore size (mm) Note First-stage stroke Note 2) 5 mm to "Full stroke" 5 mm Note 1) RZQB (through hole type) is only available for full strokes 25, 50 and 75. Note 2) Available in 1 mm increments.

, 200 50, 75, 100, 125, 150, 175, 200 CKGA series End bracket Nil Y None Double knuckle joint (with tap) CKPA series Note) A knuckle pin, cotter pins and flat washers are provided as a standard for Y.

Full stroke Note 1) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 Bore size (mm) Note First-stage stroke Note 2) 5 mm to "Full stroke" 5 mm RS Q G Note 1) RZQB (through hole type) is only available for full strokes 25, 50 and 75. Note 2) Available in 1 mm increments.

function Electrical entry Perpendicular In-line 0.5 (Nil) 5 (Z) 1 (M) 3 (L) 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW 3-wire (NPN equivalent) IC circuit 5 V,12 V 12 V Reed auto switch Solid state auto switch Relay, PLC Grommet 24 V IC circuit 5 V,12 V Diagnostic indication (2-color indication) 12 V A96V A96

Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.

1) Switches with an indicator light (except D-A76H, A96, A96V) If auto switches are connected in series as shown below, take note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.)