SMC Corporation of America
Elite Part Number Search
Search Results "MDHR3-10R-M9BSAPC"

Clean Series: Copper, Flourine and Silicon-free+Low Particle Generation, Magnet: With Magnet, Nominal Size: 10, Connecting Port: Body Side, Auto Switch: Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 5m, Number: -

Clean Series: Vacuum Suction Type, Magnet: With Magnet, Nominal Size: 10, Connecting Port: Body Side, Auto Switch: Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m, Number: -

Clean Series: Vacuum Suction Type, Magnet: With Magnet, Nominal Size: 10, Connecting Port: Body Side, Auto Switch: Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 1m, Number: -

Clean Series: Copper, Flourine and Silicon-free+Low Particle Generation, Magnet: With Magnet, Nominal Size: 10, Connecting Port: Body Side, Auto Switch: Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: -

Clean Series: 11 (Vacuum Suction Type), Magnet: D (With Magnet), Nominal Size: 10, Connecting Port: R (Body Side), Auto Switch: M9B (Solid State, Gen. Purpose, 2 Wire, Horizontal), Lead Wire: M (1m)

Clean Series: 22 (Copper, Flourine and Silicon-free+Low Particle Generation), Magnet: D (With Magnet), Nominal Size: 10, Connecting Port: R (Body Side), Auto Switch: M9PV (Solid State, Gen. Purpose, 3 Wire PNP, Vertical), Lead Wire: Z (5m)

Clean Series: 11 (Vacuum Suction Type), Magnet: D (With Magnet), Nominal Size: 10, Connecting Port: R (Body Side), Auto Switch: M9B (Solid State, Gen. Purpose, 2 Wire, Horizontal), Lead Wire: L (3m)

Clean Series: 22 (Copper, Flourine and Silicon-free+Low Particle Generation), Magnet: D (With Magnet), Nominal Size: 10, Connecting Port: R (Body Side), Auto Switch: M9P (Solid State, Gen. Purpose, 3 Wire PNP, Horizontal), Lead Wire: Z (5m)

Clean Series: 11 (Vacuum Suction Type), Magnet: D (With Magnet), Nominal Size: 10, Connecting Port: R (Body Side), Auto Switch: M9P (Solid State, Gen. Purpose, 3 Wire PNP, Horizontal), Lead Wire: L (3m)

Clean Series: 11 (Vacuum Suction Type), Magnet: D (With Magnet), Nominal Size: 10, Connecting Port: R (Body Side), Auto Switch: M9P (Solid State, Gen. Purpose, 3 Wire PNP, Horizontal), Lead Wire: M (1m)

Clean Series: 22 (Copper, Flourine and Silicon-free+Low Particle Generation), Magnet: D (With Magnet), Nominal Size: 10, Connecting Port: R (Body Side), Auto Switch: M9B (Solid State, Gen. Purpose, 2 Wire, Horizontal), Lead Wire: L (3m)

Style: Standard, Nominal Size: Ø15, Port Location: E (Axial Direction), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Style: Standard, Nominal Size: Ø15, Port Location: R (Body Side Direction), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Style: Standard, Nominal Size: Ø15, Port Location: Axial Direction, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Style: Standard, Nominal Size: Ø15, Port Location: Body Side Direction, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

14 plus items 9 and 10 from the above parts list, and can be ordered by using the seal kit number corresponding to each bore size. 28 Dual-Rod Cylinder with Rear End Lock Series CXS Made to Order Auto Switches Precautions Compact Type CXSJ Standard Type CXS With Air Cushion CXS With End Lock CXS Dimensions: 6, 10, 15 CXS6-R ZZ SS 3 3 Manual lever insertion 1.7 (mm) ZZ SS 88.5 Model CXS6-10R

LJ1-1-RJ-05 MR-JRCBL5M-H (motor/encoder/brake) 1 When the Matsushita Electric Industrial Co., Ltd. motor driver is selected, in addition to the cable, a power connector (MOLEX 5569 10R) and an interface connector (Sumitomo/3-M Limited 10126-3000VE) are also required. 2 A cable is not provided for the Mitsubishi Electric Corporation motor and brake, and therefore, the customer should arrange

LJ1-1-RJ-05 MR-JRCBL5M-H (motor/encoder/brake) 1 When the Matsushita Electric Industrial Co., Ltd. motor driver is selected, in addition to the cable, a power connector (MOLEX 5569 10R) and an interface connector (Sumitomo/3-M Limited 10126-3000VE) are also required. 2 A cable is not provided for the Mitsubishi Electric Corporation motor and brake, and therefore, the customer should arrange

MFECA0050EAB (for encoder) MFMCB0050CET (for brake) (for motor)2 MR-JCCBL5M-L (for encoder) 100 LJ1-1-G05B 75 90 5 LJ1-1-R05 30 DP9320081-2 (for motor) DP9320089-2 (for encoder) LJ1-1-Y053 (195) DP9320083-2 (for motor/brake) DP9320089-2 (for encoder) LJ1-1-Y05B 13 1 When the Matsushita Electric Industrial Co., Ltd. motor driver is selected, in addition to the cable, a power connector (MOLEX 5569 10R

In this case, make sure that the minimum bending radius of the rod is 10R or more. Loosen the hexagon socket head cap screw to adjust through 360.