Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 6 (600mm)
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 3 Port, Universal, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -