Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 16, Motor Mounting Position: In-line, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 100mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: R (Robotic Flexible Cable)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: A (10m)
Size: 40, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (with Lock), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: A (10m)
Size: 32, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: B (with Lock), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: A (10m)
Size: 40, Bearing Type: Sliding Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: with Lock, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 10m, Controller Type for (LEC, JXC): -, I/O Cable Length for LEC: -, Controller Mounting
Size: 32, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: with Lock, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 10m, Controller Type for (LEC, JXC): -, I/O Cable Length for LEC: -, Controller
Size: 32, Bearing Type: Sliding Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: with Lock, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 10m, Controller Type for (LEC, JXC): -, I/O Cable Length for LEC: -, Controller Mounting
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 10m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication
Series: Ball Screw Drive, Accuracy: Basic Type, Size: 16, Motor Mounting Position: In-line, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 100mm, Motor Option: w/Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length
Size: 32, Motor Mounting: Right Side Parallel Type, Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 100mm, Motor Option: w/Lock, Rod End: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Type: Robot Cable, Flexible Cable, Cable Length: 10m, Controller Type: -, I/O Connector: -
Use the RA face to turn it counter-clockwise (reverse actuation).
RB 2 x 4-0 threads RA RB Standard type (through hole): CLQB63/80/100 Extension locking LOCK Approx.
Main shaft Double action actuator OUT2 Main shaft Single action actuator X OUT1 OUT2 OUT1 X SUP The cam of the positioner should be set on the RA surface. SUP SUP The cam of the positioner should be set on the RA surface. The cam of the positioner should be set on the RA surface. IN + IN + IN + OUT1 is plugged.
Double clevis pins and retaining rings are included. 829 33.5 Series CLQ Dimensions: 63, 80, 100 Both ends tapped style: CLQA63/80/100 RA RB 2 x 4 x O threads RA RB Basic style (Through-hole): CLQB63/80/100 P (Rc, NPT, G) Extension locking LOCK Rod side cylinder port F Q H effective thread depth C P (Rc, NPT, G) V Head side cylinder port I D M E Z T N Dust cover (Manual unlocking unit) 4
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
RB 2 x 4-0 threads RA RB Standard type (through hole): CLQB63/80/100 Extension locking LOCK Approx.
Standard type (through hole type)/RQB, RDQB Double end tapped type: RQA, RDQA Double end tapped RA RA mm OA threads Bore size (mm) RA OA 32 40 50 M6 x 1.0 10 M6 x 1.0 10 M8 x 1.25 14 H effective thread depth C 2-P (port size) 4-N through Approx.
Main shaft Double action actuator OUT2 Main shaft Single action actuator OUT1 OUT2 OUT1 SUP The cam of the positioner should be set on the RA surface. SUP SUP The cam of the positioner should be set on the RA surface. The cam of the positioner should be set on the RA surface. IN + IN + IN + OUT1 is plugged.
Specifications [Surface finish Ra] Surface finish of the inner surface (wetted parts). A standard for measuring surface roughness which averages the peak to valley of the surface profile over a given distance (stroke). Multiple readings on a part are also averaged for Ra, but for Ra max, the worst reading is the value for that part.
Specifications [Surface finish Ra] Surface finish of the inner surface (wetted parts). A standard for measuring surface roughness which averages the peak to valley of the surface profile over a given distance (stroke). Multiple readings on a part are also averaged for Ra, but for Ra max, the worst reading is the value for that part.