Conversion cable P5062-5 (Cable length: 300 mm) 300 * To connect the teaching box (LEC-T1-3mGm) or controller setting kit (LEC-W2) to the controller, a conversion cable is required. 7 JXCE1/91/P1/D1 Series Precautions Related to Differences in Controller Versions As the controller version of the JXC series differs, the internal parameters are not compatible.

500 400 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-A AFD40-A P1=0.5 MPa P1=0.3 MPa 0.04 0.04 P1=0.7 MPa P1=0.3 MPa P1=0.7 MPa P1=0.5 MPa 0.03 0.03 Pressure drop [MPa] Pressure drop [MPa] 0.02 0.02 P1=0.5 MPa P1=0.5 MPa P1=0.3 MPa P1=0.3 MPa P1=0.7 MPa 0.01 0.01 P1=0.7 MPa 0 0 0 0 100 200 300 500 400 600 200 800 1000 400 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 57

73 psi [0.5 MPa] Peak clamping force position 112 [500] 90 [400] 0.3 MPa 44 psi [0.3 MPa] 67 [300] 45 [200] 22.5 [100] 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Shim thickness [mm] 9 CKZT -X2797 -X2798 Be sure to read this before handling the products.

Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: M (Male), Mounting: F (Rod Flange), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Male, Mounting: Double Clevis, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Male, Mounting: Rod Flange, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/

Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, PACKING SET, ACTUATOR, CQ2 COMPACT CYLINDER, S1, 100MM CQ2 PART

Nm JMHZ2-16D M3x0.5 0.59 17 - MOTOMAN-HC10 M6x12 6.3Nm 18 - M6x23 6.3 Nm M4x10 1.0Nm 19 - M8 M8 M8-MOLEX S1 S2 M4x8 1.0Nm 20 - (M4x6) (M4x6) 1.0Nm P175-2. M3x7 0.59Nm 21 - 0.7mm 22 - 5-3 1. 2. 3. 4. 1.() 2. 5m 3. 4. 5 5-4. 1.

It is possible to extend the total length of the cable up to 300 m by using a repeater. -11No.EX-OMP0025-A Wiring EX250-SAS3/-SAS5 Communication connector: M12 4-pin, plug No.

Cylinder Speed Chart Enclosure Enclosure Bore size IP65 compatible IP65 compatible Series CS1 Pressure 0.5 MPa Load rate: 50% Stroke 1000 mm Series MB/CA1 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Series Average speed (mm/s) 40 50 60 80 100 125 140 160 180 200 1100 1000 900 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Individual wiring type Horizontal actuation VQ4100

In addition, 3 of the wiring types are available with IP65 enclosures. 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ5100--04 VQ5101--04 IP65 compatible Enclosure Individual wiring type kit (Connector) C It is when the cylinder is extending that is meter-out controlled by speed

{9Ti 3 4 5 6 cylinder axis: Lo (cm) t 300 ; 200 i'i 100 = P e .F 20 '10 9' -4!2 E 1 0 E E _ E 5 E E c r l 0 1 2 3 4 5 6 7 I I 101112131415 Distance from cylinder axis: Lo (cm) Example The required load, Fo =100(N) and the moment arm, L0 = Bcm refering to Data 1, draw a vertical line from the 8cm value of the horizontal axis.

T|lULTI'PURPOSE APPLICATIONS FOF USE AS: PORT'A' PORT "P" PORT "E'' Opg.ltng PrEsluEr 28" vacuum to 300 PSIG. (2oKgtcflf) 2-Way Normally Closed O!

{9Ti 3 4 5 6 cylinder axis: Lo (cm) t 300 ; 200 i'i 100 = P e .F 20 '10 9' -4!2 E 1 0 E E _ E 5 E E c r l 0 1 2 3 4 5 6 7 I I 101112131415 Distance from cylinder axis: Lo (cm) Example The required load, Fo =100(N) and the moment arm, L0 = Bcm refering to Data 1, draw a vertical line from the 8cm value of the horizontal axis.