Size: 40, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 400mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R1 (1.5m)
Size: 32, Motor Mounting Position: U (Bottom Mounting), Stroke: 400, Motor Option: w/o Option, Stroke Adjustment Unit: W (Both Sides), Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C51 (JXC51, Parallel NPN, Step Data Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 7 (Screw Mounting), Communication Plug Connector
Size: 32, Motor Mounting Position: D (In-line), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 400mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 8 (8m), Controller Type - LEC, JXC: C61 (JXC61, Parallel PNP, Step Data
Size: 25, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 400mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65,
Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: C (5mm), Stroke: 600mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 5m, Driver Type: 92 [LECSN2-T EtherNet
Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: B (10mm), Stroke: 50mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m, Driver Type: 92 [LECSN2-T EtherNet
Series: LEFB (Belt Drive), Size: 40, Motor Mounting Position: Top Mounting Type, AC Servo Motor: S4 (400W Output, Incremental Encoder), Lead: S, Stroke: 2500mm, Motor Option: None, Auto Switch Compatibility: None, Positioning Hole: Housing B, Bottom, Cable: S (Standard Cable), Cable Length: A (10m)
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 40, Motor Mounting Position: L (Left Side Parallel), Motor Type: V8 (400W Output, Absolute Encoder), Lead: B (LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 750mm, Motor Option: w/o Option, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Cable Type: S (Standard Cable), Cable
Accuracy: Basic, Motor Mounting Position: R (Right Side Parallel), Motor Type: V8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: B (10mm), Stroke: 200mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/vent hole tap), Motor Option: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: D (Double Clevis)
Accuracy: Basic, Motor Mounting Position: R (Right Side Parallel), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: B (10mm), Stroke: 200mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/vent hole tap), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: D (Double Clevis), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver Type:
Accuracy: Basic, Motor Mounting Position: R (Right Side Parallel), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: L (2.86mm), Stroke: 300mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m, Driver Type: S2
Accuracy: Basic, Motor Mounting Position: R (Right Side Parallel), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: L (2.86mm), Stroke: 400mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m, Driver Type: S2
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 40, Motor Mounting Position: In-line, Motor Type: T8 (400W Output, Absolute Encoder), Lead: B (LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 200mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Cable Type: R (Robotic Cable, Flexible Cable), Cable
Size: 80, Motor Mounting Position: FR (Right), Motor Type: V8 (AC Servo w/ Absolute encoder, 400W output, LECY compatible), Lead (mm): M (1/9 reduction: LET80: 14.44, LET100: 26.67), Stroke: 1000mm, Motor Option: B (with Lock), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: U2 (200-230V, LECYU2-V8), I/O Cable Length: 1 (1.5m)
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: C (5mm), Stroke: 150mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: A (10m), Driver Type