Size: 25, Motor Mounting Position: Left, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Foot, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: (JXCM1 CC-Link, Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting
Size: 25, Motor Mounting Position: Left, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Foot, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: (JXCM1 CC-Link, Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting
Size: 25, Motor Mounting Position: Left, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Male, Mounting: Foot, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: (JXCM1 CC-Link, Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting
Size: 25, Motor Mounting Position: Left, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Male, Mounting: Foot, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: (JXCM1 CC-Link, Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting
Size: 25, Motor Mounting Position: Left, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 400mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: (JXCM1 CC-Link, Direct Input Type, I/O Cable Length for LEC
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Lead: 16: 5mm; 25: 6mm; 32, 40: 8mm, Stroke: 150mm
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Lead: 16: 5mm; 25: 6mm; 32, 40: 8mm, Stroke: 300mm
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Lead: 16: 5mm; 25: 6mm; 32, 40: 8mm, Stroke: 100mm
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Lead: 16: 5mm; 25: 6mm; 32, 40: 8mm, Stroke: 200mm
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: H (High Precision), Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: H (High Precision), Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o