Green LED lights up Indicator light Lead wire Oil resistant heavy duty vinyl cord, 6, 0.5mm, 2 wire (Brown, Blue [Red, Black]), 3m Impact resistance 1000m/s Insulation resistance 50M or more at 500VAC (between lead wire and case) Withstand voltage 1000VDC for 1 min.

to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown, Blue [Red, Black]) 0.5m D-A96: Oil resistant heavy duty vinyl cord 2.7 0.15mm x 3 wire (Brown, Black, Blue [Red, White, Black]) 0.5m Insulation resistance 50M

Oil proof vinyl heavy insulation cable 2.7 1.5mm2 X 3 wire (red, white, black)0.5m, 0.18mm2 X 2 wire(Red, black) Impact resistance . . . . 1,000m/s2(102G) Insulation resistance . . 50M or more under the test voltage 500VDC (between case and cable) Withstand voltage . . . . 1000VAC for 1 min.

D-A90(V) Red LED lights when ON Indicator light None Lead wire .Oil proof heavy duty vinyl cord, 2.7, 0.5m D-A90 (V), D-A93 (V) 0.18mm x 2 cores (brown, blue [red, black]) D-A96 (V) 0.15mm x 3 cores (brown, black, blue [red, white, black]) Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage . 1000VAC for 1min.

300 or less with 12VDC, 600 or less with 24VDC Power supply voltage 12 to 24VDC (ripple 10% or less) Current consumption 20mA or less (without load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (no freeze nor condensation) Environmental resistance Voltage resistance 1000VAC for 1 min between external terminals and case Insulation resistance 50M

consumption Withstand voltage Insulation resistance Noise resistance Vibration resistance Impact resistance Weight Enclosure Port size (Rc, NPT, G) 1s or less Note 3) Hysteresis mode: Variable (can be set from 0), Window comparator mode: Fixed (3 digits) 12 to 24VDC (ripple 10% or less) 160mA or less 170mA or less 150mA or less 1000VAC for 1 min. between external terminal block and case 50M

Install a filter strainer of about 50m on the inlet side of the piping. 4. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 5. Always tighten threads with the proper tightening torque.

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 5 (5m), Controller Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting,

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting,

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 50mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): LECA6, Step Data Input Type, PNP, I/O Cable Length for LEC: 5m, Controller Mounting: Screw Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 50mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 8m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 50mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication

Connector for DIN Terminal Rated voltage Light/Surge voltage suppressor (D) With surge voltage suppressor (DS) Light/Surge voltage suppressor (DZ) 100 VAC 200 VAC 24 VDC GDM2A-S1 GDM2A-S2 GDM2A-S5 GDM2A-Z1 GDM2A-Z2 GDM2A-Z5 GDM2A For other rated voltages, please consult with SMC. 4-7-12 13 3 Port Direct Operated Poppet Solenoid Valve Rubber Seal Series VT317 Dimensions Conduit: VT317-C Grommet

Connector for DIN Terminal Rated voltage Light/Surge voltage suppressor (D) With surge voltage suppressor (DS) Light/Surge voltage suppressor (DZ) 100 VAC 200 VAC 24 VDC GDM2A-S1 GDM2A-S2 GDM2A-S5 GDM2A-Z1 GDM2A-Z2 GDM2A-Z5 GDM2A For other rated voltages, please consult with SMC. 4-7-12 13 3 Port Direct Operated Poppet Solenoid Valve Rubber Seal Series VT317 Dimensions Conduit: VT317-C Grommet

Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Body Size: 40, Motor Type: F (High Performance, Step Motor 24 VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 600mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: S5 (5m), Controller: C9H (JXC9H

Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Body Size: 40, Motor Type: F (High Performance, Step Motor 24 VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 500mm, Motor Option: B (w/Lock), Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: S5 (5m), Controller: C9H (JXC9H

Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, DBL ACTING, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, S5, 100MM CG CLEAN-ROOM, .00000 lb

Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, CLEAN ROOM, ACTUATOR, MGF COMPACT GUIDE CYLINDER, S5, 100MM MGF CLEAN ROOM, 26.13022 lb, ModelBore size (mm)Standard stroke (mm) 305075100MGF1001007.08.29.611.0

Optional auto switches can be mounted on 4 faces of the body.Low profile, compact, guide table for clean room applications , Large diameter guide rod enables cylinder to handle eccentric loads applied from any direction within a 360 angle, Grade 2 particle generation, Auto switch capable, CYL, GUIDE, CLEAN ROOM, ACTUATOR, MGF COMPACT GUIDE CYLINDER, S5, 100MM MGF CLEAN ROOM, 23.14853