Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: Screw Mounting
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: Screw Mounting
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Option: Screw
Oscillation Angle A: 320°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 10, Size: 50, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MOTOR CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, 0.55115 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 14.33004 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP NPN, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 4.07855 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP NPN, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 1.98416 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting