D L 1 (2) Winding of sealant tape 100 2d When screwing together pipes and fittings, etc., be Mandrel certain that chips from the pipe threads and sealant do not get inside the pipe. Also, when the sealant tape is used, leave approximately 1 thread ridge exposed at the end of the threads.
L..k.g.: Port to porl (internal) not 1o exceed 0.m7 cubic feet per minule at 100 PSIG (6.9 Kgtcm'). Op.r.Sng Pr..rur..! 28 'Vacuuh to 30o FSIG (20 Kglrcm?).
Also, when the sealant tape is used, leave approximately 1 thread ridge exposed at the end of the threads. 100 2d D L 1 = Mandrel 5 - 2. Specific Product Precautions (2) (3) Check the model, type and size before installation.
AS-FE AS321F-03-W2 R3/8 AS421F-04-W2 R1/2 Applicable tubing materials FR double layer, FR soft nylon KE Note 1) Meter-out and meter-in types can be visually differentiated by the lock nut. The lock nut on the meter-out type is zinc chromated, while the meter-in type is black zinc chromate plated. Note 2) : Brass parts are electroless nickel plated, provided as standard.
100 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations AS4201FSl, AS4211FSl AS3201FSl, AS3211FSl 12, 13, 16 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10, 11, 12 1500 1000 08, 09 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 10, 11 06, 07 1000 500 500 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate
Elbow Universal Elbow body Body A Body A Connection thread size Proper tightening torque [Nm] NPT, R1/8 3 to 5 NPT, R1/4 8 to 12 NPT, R3/8 15 to 20 NPT, R1/2 20 to 25 Body B Body B Caution Chamfered area for female thread By chamfering as shown in the table below, machining of threads is easier and effective for burr prevention.
Nut Insert bushing Nut Insert bushing LQ1E3A-R3 3 4-11 LQ1-4N11 LQ1-4B11 2-03 LQ1-2N03 LQ1-2B03 LQ1E4A-R2 4 4-13 LQ1-4N13 LQ1-4B13 3-07 LQ1-3N07 LQ1-3B07 LQ1E4A-R3 4 4-13 LQ1-4N13 LQ1-4B13 2-05 LQ1-2N05 LQ1-2B05 LQ1E4A-R4 4 4-13 LQ1-4N13 LQ1-4B13 2-03 LQ1-2N03 LQ1-2B03 LQ1E5A-R2 5 6-19 LQ1-6N19 LQ1-6B19 3-11 LQ1-3N11 LQ1-3B11 LQ1E5A-R3 5 6-19 LQ1-6N19 LQ1-6B19 3-07 LQ1-3N07 LQ1-3B07 LQ1E5A-R4
Body size Port size KKA3 S-01 M KKA3 P-01 M R1 / 8 R1 / 8 1 / 8 KKA3 S-02M 1 / 8 KKA3 P-02M R1 / 4 R1 / 4 KKA3 S-03 M KKA3 P-03 M R3 / 8 R3 / 8 KKA4 S-02M KKA4 P-02M R1 / 4 R1 / 4 KKA4 S-03 M 1 / 4 KKA4 P-03 M 1 / 4 R3 / 8 R3 / 8 KKA4 S-04 M KKA4 P-04 M R1 / 2 R1 / 2 KKA6S-03 M KKA6P-03 M R3 / 8 R3 / 8 KKA6S-04 M KKA6P-04 M 1 / 2 1 / 2 R1 / 2 R1 / 2 KKA6S-06M KKA6P-06M R3 / 4 R3 / 4 Built-in
(mm) Model R3/8 KQGT04-00 KQGT06-00 KQGT08-00 KQGT10-00 KQGT12-00 4 6 8 10 12 R1/4 10 R3/8 R3/8 12 R1/2 Straight Union Straight Union Union "Y" Union "Y" Applicable tubing O.D. (mm) Model Applicable tubing O.D.
Connection thread size Tightening torque [Nm] R1/8 3 to 5 R1/4 8 to 12 R3/8 15 to 20 R1/2 20 to 25 4) Reuse 1. Normally, fittings with a sealant can be reused 2 to 3 times. 2. To prevent air leakage through the sealant, remove any loose sealant stuck to the fitting by blowing air over the threaded portion. 3.
x) (24s)10.28 (261) 'r0.91 (2n) 11.9 (293) 1217 (309) 12.ffi (325) 13.,r3 (341) L2 1.57 (40) 2.20 (56) 2.83 \72) 3.46 (88) 4.09 004) 4.72 020) (136) s.98 \152) 6.61 (168) 7.24 (184) 7.47 (200) (26) 9.13 (232) 9.76 \244) 1039 ( 4 ) '11'o2 (280) 11.66 (2e6)12.2a (32) 12.91 (328) t3 0.63 o6) 1.26 (32) 1.89 (4s) (64) 3.15 (80) 3.78 (e6) 4.41 1112) 5.04 (128) (i44) 6.30 (160) 6.93 (176) /.5tt
Series: LEKFS, Size: 25, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 100, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: R3 (3), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)
Series: LEKFS, Size: 25, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 100, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: R3 (3), Controller: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)
Series: LEKFS, Size: 16, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 100, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R3 (3), Controller: C61 (JXC61, Parallel I/O), Controller Mounting: 8 (DIN Rail Mounting), Communication Plug
Series: LEKFS, Size: 25, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 100, Motor Option: B (with Lock), Seal Band Stopper: Standard, Actuator Cable Type, Length: R3 (3)
OUT port Mounting VBA1: Tightening torque of 12 to 14 Nm (R1/4) VBA2: Tightening torque of 22 to 24 Nm (R3/8) Drain port Rc1/4 (4) O-ring : Mount the O-ring in the groove on the joint of the tank at the back of the booster regulator.
VBAT-M35C () () 1 1 1 1 SMC ( 3 ) VBA2 VBA1 () 30 IN 1.5MPa VBA1A 2MPa, O 1.5MPa OUT VBATA1--X104 VBAT-V1 OUT 4 11 () 1 VBAT05A1-U-X104 VBAT10A1-U-X104 1.5MPa Q235B 5L 10L 075 6.6kg 11.5kg IN 3/8 VBAT-V1 OUT 3/8 1/2 1/4 VBA1 VBA1/VBA2 TSG R0003-2007 2 () IN (I) :VBA1 4VBA2 8 6 : OUT VBA2 (J) Rc3/8 VBA1 OUT IN Rc1/2 Rc3/8 () OUT VBA1 12~14Nm(R1/4) VBA2 22~24Nm(R3
VBA2: Tightening torque: 22 to 24 Nm (R3/8) VBA4: Tightening torque: 28 to 30 Nm (R1/2) (3) Change of the booster regulator OUT port plug VBA2, 4: Tightening torque: 24 Nm (M10) booster regulator by applying the seal tape. with a monkey spanner. Booster regulator Air tank Groove O-ring (4) O-ring
T-X104 VBA4 4 VBA2 1 O VBA4 1 1 / VBAT-T 1 1 1 / VBAT-M36 / VBAT-M36C () () 1 1 1 SMC ( 3 ) () 30 IN 1.0MPa OUT VBATA1--X104 O VBAT-V1 OUT 4 13 () 1 VBAT20A1-T-X104 VBAT38A1-T-X104 1.0MPa Q235B 22L 38L 075 15kg 26kg VBAT-V1 IN 1/2 OUT 1/2 3/4 1/4 VBA2/VBA4 TSG R0003-2007 2 () IN :VBA2 8VBA4 8 10 (I) 6 : Rc3/8 OUT (J) OUT Rc1/2 IN Rc1/2 () OUT VBA2 22~24Nm(R3
VBA11A 150 337 370 307 163 160 100 200 Rc 3/8 257 60 278 130 regulator A B C D E F G H I J K L M URL http://www.smcworld.com Rc 1/4 20 Rc 1/2 39 IN port Rc3/8 Rc 3/8 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3 5207 8249 Fax: +81 3 5298 5362 170 180 120 312 2008 SMC Corporation All Rights Reserved Assembly dimensions OUT port (J) Maintenance 411 IN port (I) Akihabara