Fluid Table (1) Rated Voltage-Electrical Entry-Electrical Option Standard specifications Option (1) Made to Order (2) Water (standard) Turbine oil High temperature water (D, E) Air X500B Vacuum (up to 1.3 x 10 2 Pa) X500B For pure water X500 G C Class B D, T Class H G, C T S Note) S L, Z L, Z S Note) Surge voltage suppressor is attached in the middle of lead wire.
How to Order 25A-LEFS 25 H R B 200 S 1 6N 1 q r w e t u y i o !0 !1 !
U Min. bending radius of lead wire 10 Auto switch K M E J S B + Stroke L + Stroke L A + 2 strokes Note) The drawings above show type D-A7 and D-A8 reed switches. The values shown inside ( ) are for switches other than types D-A7 and D-A8. S and U dimensions for connector type auto switches (D-A7C, D-A80C, and D-J79C) are 7mm greater.
-~-Micro-Mist Separator '-Made to order s ecifications" J Drain guide 1/48 female thread R IN OUT reversal 250 1/4 T Element service indicator 350 3/8 450 1/2 550 3/4 650 850 11/2 Thread B Bracket C N.C. auto drain(AMH150-550) o N.O. auto drain Rc (plj F GlPFl .. Refer to the table below for combination N NPT of accessories and optional specifications.
Number of auto switches Number of fingers Nil S n 2 2 finger 2 pcs. 1 pc. n pcs.
How to Order 11 LEFS 100 B 1 1 S K 6N 16 w e r t u y o i !0 !1 !2 !
mm/s *1 Cushion Rubber bumper Allowable kinetic energy [J] 0.022 0.038 0.055 0.09 0.15 0.26 0.46 0.77 1.36 2.27 Rod end thread Female thread Symbol Stroke length tolerance +1.3 0 mm Note) Rubber bumper Note) Stroke length tolerance does not include the deflection of the bumper.
Cable length or less customer. + Speed with no load (mm/s) 33 or m ore 100 or m ore 200 or m ore Speed with no load (mm/s) 33 or m ore 100 or m ore 200 or m ore Please refer to Table 1 Applicable auto switch Select D, built-in magnet, when the auto switch is required. Select Nil, no magnet, when the auto switch is not required.
Deionized water (with an electric conductivity of approximately 1 S/cm) can be used, but may lose its electric conductivity. Also, if a facility supplying deionized water is used, the thermocon may be damaged by static electricity. When installing the product into a rack, it should be designed that the product weight is held with the bottom surface of the product.
NIL S Nominal size 10 15 Connecting port E: Axial side R: Body side Port Port Applicable Auto Switches/Refer to pages 797 to 850 for further information on auto switches.
compressor is 30mg/m3(ANR) (ANR) Accessories (Options) Applicable models AM150 AM250 AM350 AM450 AM550 AM650 AM850 Bracket assembly With cap bolt, BM51 BM52 BM53 BM54 BM55 BM56 BM57 spring washer Symbol AM Order Made P.4.6-6 How to Order AM 250 03 J B Options Body size Accessories (Options) Drain guide 1/4B female thread INOUT reversal Element service indicator None 150 250 350 450 550 650 850
Symbol AMD 4.6-7 Micro Mist Separator Series AMD AMD150 to AMD850 How to Order AMD 250 03 J B Body size Options J Drain guide 1/4B female thread R IN R OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Symbol Description None Bracket T Element service indicator B N.C. auto drain C N.O. auto drain D Please refer to p.4.7-7 regarding How to Order of case
BM51 BM52 BM53 BM54 BM55 BM56 BM57 How to Order AME 250 03 R B Option R INOUT reversal Body size HAl Accessories (Options) 150 250 350 450 550 650 850 1/8 1/4 3/8 1/2 3/4 None B AT With bracket IDl Port size 1/8B 01 02 03 04 06 10 14 20 2B 1 Thread 1/4B AMG 11/2 3/8B Rc(PT) F G(PF) N NPT 1/2B AFF 3/4B 1B AMl 11/2B Symbol Related poroducts AME Note) Refer to p.4.7-7 for "How to Order" case
Options) Applicable model Bracket assembly AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Symbol BM51 BM52 BM53 BM54 BM55 BM56 BM57 spring washer With cap bolt, AMF Refer to ''Precautions" on p.4.6-33. 4.6-27 Odor Removal Filter Series AMF AMF150 to AMF850 How to Order AMF 250 03 R B Option R IN, OUT reversal Body size Accessories (Optional) 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850
With spring washer BM51 BM52 BM53 BM54 BM55 BM56 BM57 Condition of inlet air Pressure: 0.7MPa Temperature: 25C Relative humidity: 100% How to Order AMG 250 03 J B Liquid water content (Water droplet content): 1.5g/m3 (ANR) Options Body size Compressed air flow: Rated flow of each model J Drain guide 1/4B female thread R IN-OUT reverse direction 1/8 1/4 3/8 1/2 3/4 1 150 250 350 450 550 650 850
Symbol Order Made P.4.6-21 4.6-15 Micro Mist Separator with Prefilter Series AMH AMH150 to AMH850 How to Order AMH 250 03 J B Body size Options J Drain guide 1/4B female thread R IN/OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Description None Bracket Symbol T Element service indicator B N.C.auto drain C N.O.auto drain D Note) Refer to p.4.7-7
DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatics Finland OY FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Ipari Automatizlsi Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. LATVIA SMC Pneumatics Latvia SIA NETHERLANDS SMC Pnuematics BV. NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp.z.o.o.
NIL S Nominal size 10 15 Connecting port E: Axial side R: Body side Port Port Applicable Auto Switches/Refer to pages 797 to 850 for further information on auto switches.
type y Stroke [mm] Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 50 50 to to 1200 1200 Nil Without option B With lock Nil Without cable S Standard cable R Robotic cable (Flexible cable) o Actuator cable length [m] !
Speed with no load (mm/s) 33 or m ore 100 or m ore 200 or m ore Speed with no load (mm/s) 33 or m ore 100 or m ore 200 or m ore L[]ZB[]3L[][][]A3 L[]ZB[]3M[][][]A3 L[]ZB[]3H[][][]A3 L[]ZB[]5L[][][]A5 L[]ZB[]5M[][][]A5 L[]ZB[]5H[][][]A5 Rated thrust (N) 196 or m ore 117 or m ore 72 or m ore Rated thrust (N) 80 or m ore 43 or m ore 24 or m ore electric cylinder LZ series and the directional