SMC Corporation of America
Elite Part Number Search
Search Results "LEC-GEN1"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Series LECP6 controller has two available modes for the setting software and teaching box.  In the easy mode, the operation can be started by only setting the speed, position, etc.  Using the normal mode allows a further detailed setup.  A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator to

CD-ROM SET, ACTUATOR, ELECTRIC ACTUATOR, 21, LE ELECTRIC ACTUATOR, 1.03 lb

PROFIBUS GATEWAY CONTROLLER, PROFIBUS GATEWAY CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 22, LE ELECTRIC ACTUATOR, .37478 lb

Other items in the step data should be input beforehand using the controller setting kit (LEC-W2) and teaching box (LEC-T1). 17 No.JXC-OMW1019-A 8. Wiring of cables / Common precautions Warning (1) Adjusting, mounting or wiring change should never be done before shutting off the power supply to the product.

Connect the communication cable LEC-W2A-C to the USB port of the PC using the USB cable (LEC-W2-U). The message shown below will appear, as the driver has not yet been installed. iii. Open the Windows Start menu, right-click on Computer, select Properties and thereafter Device Manager.

Connect the communication cable LEC-W2A-C to the USB port of the PC using the USB cable (LEC-W2-U). ii. Right-click the Start menu, and select "Device Manager". Right-click 7 - iii. The COM No. is shown next to the "SMC Serial Port" in the "Ports (COM&LPT)". (In the case of the lower figure, the COM No. is "3".)

Connect the communication cable LEC-W2A-C to the USB port of the PC using the USB cable (LEC-W2-U). ii. Right click the Windows logo at the lower left of the desk top, and select Device manager. iii. Check the COM number for the RS485 communication from the Ports (COM & LPT) device SMC Serial Port. In this example it is shown as COM8.

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. New Style piping adapter attachment , Easy maintenance , Detach equipment

LEC-OM09402 PRODUCT NAME AC Servo Motor Driver (Parameter Configuration using Setup software (MR Configurator2TM)) MODEL / Series / Product Number LECS Series CONTENTS CONTENTS . 1 Introduction . 5 1.

Cable between branches Branch cable LEC-CG2Upper level device LATH7-1 Branch connector Terminating White LEC-CGD LEC-CGR SD+ SD+ SDSDBlack SG Branch cable LEC-CG1GND Common with GND of each controller LATCA_3 LATCA_2 LATCA_1 Warning The power supply 0 V of all the controllers used for serial communication should be at the same potential as that of the master communication device.


USB drivers for communication cables (LEC-W2A-C and LEC-W2-C) can also be downloaded.
The controller setting software can be downloaded from here.
Note) Even if you download the controller setting software, a communication cable (LEC-W2A-C) or USB cable (LEC-W2-U) is always required.

LEC-OM07304 (Doc No. JXC-OMT0068) Simplified edition PRODUCT NAME AC Servo Motor Driver (MECHATROLINK-II type) MODEL / Series / Product Number LECYM Series Contents Introduction . 6 1. Procedure before operation . 7 1.1 Flow chart . 7 2.