10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40 50 60 70 80

(Refer to p.4.9-5) Caution Model Recommended SMC speed controller Caution Model Elbow Straight In-line REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC32 AS3201F-01-08-X214 AS3001F-08-X214 AS3201F-01-08-X214 REC40 AS3201F-02-08-X214 AS3001F-08-X214 AS3301F-02-08-X214 4.9-3 Be sure to read before handling.

9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018-10-MT 0.8 80 0.7 70 Circulating fluid pressure [MPa] 0.6 60 0.5 Pump head [m] Available area 50 0.4 Outlet60Hz 40 0.3 30 Outlet50Hz 0.2 20 Return port 0.1 10 Available area 0.0 0 0 5 10 15 20 25 5 Circulating fluid flow [L/min] Fig 9.6-3 Pump capacity(HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT) 9.6.4 HRS012--20-T, HRS018

Model K VCKL0604-02F H KFN-06-X2 K VCKL0806-02F H KFN-08-X2 K VCKL1075-02F H L Union nut C3604BD + Ni plated 1 1 set unit KFN-10-X2 K VCKL1008-02F H K VCKL1209-02F H KFN-12-X2 K VCKL-02F H K VCKL0604-02F H KFS-06 K VCKL0806-02F H KFS-08 K VCKL1075-02F H M Sleeve Nylon 1 1 set unit KFS-10 K VCKL1008-02F H VNA VNB K VCKL1209-02F H KFS-12 SGC SGH N Gasket VCKK-4-1 Nylon 1 10 set unit VNC VNH

(mm) ~-' Mounting thread( Application: Refer to listfJ) 02 92 16-.16 04 04 20-'20 06 ffl 25-25 08 "8 32-"32 10 '10 40-140 13 " 1 3 50-. 50 Pad type Vacuum Entry Lisl8 Vacuum Entry Mounting ~10 .16 m . 32 1'4O 1'5!1, N4 ~4 Nylon tube li ~.

63 BA-01 20 BA-02 25 BA-32 32 BA-04 40 BA-05 50 BA-06 63 BA-08 80 BA-10 100 Courtesy of Steven Engineering, Inc. !

Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I

Metric Size Applicable tubing 23 04 06 08 10 12 3.2 4 6 8 10 12 AS1002Fm TMH-23J TMH-04J TMH-06J AS2002Fm AS2052Fm TMH-06 TMH-08 AS3002Fm TMH-07 TMH-10 TMH-12 AS4002Fm TMH-13 Tubing size Applicable model The applicable TMH for the AS1002Fm-02 is not available.

HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

Metric Size Applicable tube Tube size 4 6 8 10 12 23 04 06 08 10 12 Applicable series 3.2 TMH-23J TMH-04J TMH-06J AS1002F AS2002F AS2052F AS3002F AS4002F TMH-06 TMH-07 TMH-08 TMH-10 TMH-12 TMH-13 Holder for speed controller Note) The applicable TMH for AS1002F-02 is not available.

11 14 20 20 27 16 19 24 34 34 42 10 10 14 22 22 25 10 10 14 22 22 25 14 14 20 30 30 32 14 14 20 30 30 32 28 28 40 60 60 64 50 12.5 CS1 64 16.5 80 23.5 C76 80 23.5 119 28.5 Note) For a double clevis, a pin (cotter pin) and a flat washer are equipped as standard.

0.0 5 0 10 20 30 5 0 10 20 30 Circulating fluid flow[L/min] Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS040--20-(BJM)) 9.6.2 HRS040--20-T,-MT 0.5 50 Available area 0.4 40 Circulating fluid pressure[MPa] Pump head[m] Outlet50Hz Outlet:60Hz 0.3 30 0.2 20 0.1 10 Return port Available area 0 0.0 0 10 20 30 40 Circulating fluid flow[L/min] Fig. 9-8 Pump capacity(HRS040--20-T/-MT)

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

0.7 70 0.6 60 Circulating fluid pressure[MPa] 0.5 50 Pump head[m] Availavel area 0.4 40 Outlet60Hz 0.3 30 Outlet50Hz 0.2 20 0.1 10 Return port Availavel area 0.0 0 10 20 30 40 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS060--20-(BJM)) 9.7 Required facility water flow (For water-cooled type) 30 Facility water flow rate[L/min] 25 20 15 10 5 0 0 10 20 30 40 50 Facility water inlet

) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 1/2 3/4 1 1 1/4 1 1/2 2 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 2.7 2.7 2.7 5.1 5.1 5.0 10.3 10.3 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 56 56 56 76 76 76 101 101 71 71 71 104 104 104 129

M Weight (g) AS AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 7.8 8.9 11.0 15.2 18.5 8.9 11.0 15.2 18.5 11.0 15.2 18.5 20.9

to 1.0 MPa) Operating Parameters Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Vacuum to 3500 psig (24.1 MPa) 1) Vacuum to 300 psig (2.1MPa) 5000 psig (34.5 MPa) 10 psig (69 MPa) 40 to 160F (40 to 71C) (No freezing) 2) 0.09 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 3) 4 x 10-9 Pam3/sec 4) Ra max 15 in. (0.4 m) Option: 10 in.

-06-X214 Caution 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Universal type (throttle valve) 10-AS2301F-01-06-X214 10-AS1301F-M5-06-X214 1.