SMC Corporation of America
Elite Part Number Search
Search Results "IL220-N02-T"

(at 500 VDC) between terminals and case Standards CE/UKCA marked, UL (CSA) -21No.PF-OMJ0016-J Specifications of piping port Model 01 02 N01 N02 F01 F02 C4 C6 C8 N7 4 8 6 1/4 (5/32") (5/16") Thread type (Port size) Rc Rc NPT NPT G G OneOneOneOne1/8 1/4 1/8 1/4 1/8 1/4 touch fitting touch fitting touch fitting touch fitting Straight without flow adjustment valve 95 g 125 g 55 g Bottom entry

Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. q w Locking nut t Wiring Warning e 1. Since the light emitting diode (LED) is used for the light assembly for 24 VDC, there are 2 terminals and polarity. One is + for red load wire and the other is for black load wire. Light will not light up if wired incorrectly. 2.

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: T (

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: T (Calibration Certificate)

Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)

Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product)

Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product)

Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: T (Calibration Certificate)

Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only)

Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: T (Panel Mount Adapter for w/

This is a legacy product, and replaced byY410-N02-A, T-TYPE SPACER, AIRLINE EQUIPMENT, AC MASS PRO, 22, AC MASS PRO NO SIZE RATING, .14960 lb

RoHS 3-Screen Display High-Precision Digital Pressure Switch: For Air ISE70/71 Series How to Order ISE70 02 M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certicate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/41 T Calibration certicate Option 2 Symbol

Instantaneous flow: L/mincfm Accumulated flow: Lft3 Port size C8 02 8 (5/16") One-touch fitting Rc1/4 NPT1/4 G1/4 Note 4) N02 F02 Option 2 Note 4) ISO1179-1 compliant Made to Order With bracket (For without flow adjustment valve) S R Nil With bracket (For with straight type flow adjustment valve) Piping entry direction ZS-33-M ZS-33-MS With 3 selftapping screws Nil L With 2 selftapping screws