Bore (mm) 125 140 160 180 200 250 300 H A H1 L1 H A I type single knuckle Y type double knuckle 125 65 125 140 160 180 / 200 250 300 100 156.5 I-12 Y-12 125 3.5 65 50 110 105 161.5 I-14 Y-14 140 3.5 76 50 110 110 170.5 I-16 Y-16 155 3.5 83 56 120 125 193.5 I-18, I-20 Y-18, Y-20 160 3.5 88 63 135 160 245.5 I-25 Y-25 195 3.5 106 71 160 175 266.5 I-30 Y-30 210 3.5 115 80 175 Accessory SCS1

MB1 Rod End Nut Y Type Double Knuckle Joint CA2 ND hole H10 Shaft d9 CS1 Material: Cast iron CS2 Applicable bore size (mm) E1 L1 MM NX NZ U1 A1 RR1 NDH10 Part no.

NX NZ Material: Rolled steel C85 Applicable bore size (mm) 125 140 160 180 200 250 300 Y-12 +0.084 0 +0.3 +0.1 0.1 0.3 32 25 64 Part no. 8 46 100 M30 x 1.5 27 42 D C B d H Y-14 125, 140 160 180 200 250 300 NT-12 NT-16 NT-18 NT-20 NT-25 NT-30 0.1 0.3 +0.084 0 +0.3 +0.1 36 28 72 8 48 105 M30 x 1.5 30 47 53.1 44 46 18 M30 x 1.5 C95 Y-16 +0.1 0 +0.3 +0.1 0.1 0.3 40 32 80 8 55 110 M36 x 1.5 34

reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90 °C, Cooling capacity: 2 kW, 8 kW, 15 kW, and 30 kW, Temperature stability: ±0.3 °C, Ideal for ordinary temperature and high temperature processes, Front Panel for HRW008

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: NZ (N+Z)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: S (Pump Inverter Type), Option: NZ (N+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: NZ (N+Z)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: NZ (N+Z)

Cooling Capacity: 008 (8 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type), Option: NZ (N+Z)

Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: None, Option: NZ (N+Z)

Cooling Capacity: 030 (30 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: None, Option: NZ (N+Z)

The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type).? Energy saving is substantially increased by exchanging cooling water and heat directly.? The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly