Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
(Except C kit) F, P, T and S kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. The number of max. stations differs from kit to kit. (Refer to the table below.)
Do not If using the product in an interlocking circuit Provide a double interlocking system, for example a mechanical system. Check the product for proper operation. Otherwise malfunction can result, causing an accident.
40 J (5) Drain guide 1/4 AFM30/40 Float type auto-drain (N.C.) (4) Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right Left AFM20 to 40 N (1) Drain cock with barb fitting: 6 x 4 nylon tubing Float type auto-drain (N.O.) (4) W F (2) AFM30/40 D AFM30/40 Note 1) Drain guide is NPT 1/4 (applicable to AFM30 and 40), and the exhaust port for auto-drain comes
Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH300-A-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
Micro Mist Separator Series AFD20/30/40 How to Order 03 BD F 30 2R AFD Option Symbol 2 6 8 C J R Description Applicable model Micro mist separator Accessory AFD20 to 40 AFD20 to 40 AFD30/40 AFD20 AFD30/40 AFD20 to 40 Metal bowl Port size F.R.L. Description With bracket Float type auto-drain (N.C.) Float type auto-drain (N.O.)
Manifold block assembly number differs according to an attached lead wire assembly based on the connector specification (Single, Double). Select an appropriate part number from among the manifold block assembly numbers shown below.
This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3.
How to Order M Type Connector Assembly ON OFF ON OFF Lead wire length Positive common specifications Nil 6 10 15 20 25 30 50 SX100-40-4S300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For single solenoid: Normal operating state. Switching of valve is based on an electric signal from the connector.
If 12VDC specifications are required, enter "12" at the end of the assembly part number. 1 2 1 2 P N D side SZ3000-40-6A-D For flat cable 20 pins SZ3000-40-5A-D 1 2 1 2 P N D side SZ3000-40-8A-D For flat cable 10 pins SZ3000-40-7A-D A connector block assembly can be shipped as an assembly only in the case of double wiring.
This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3.
28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.
style Double clevis style B L F G D Note) 10 16 20 25 28 10 mm 16 mm 20 mm 25 mm 28 mm 16 10, 20, 30, 40, 50, 60 20 10, 20, 30, 40, 50, 60 25 10, 20, 30, 40, 50, 75, 100 28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.
500 500 500 0 0 0 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 Mey 1500 1500 1500 1500 L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 1000 1000 1000 1000 Wall L5 Y 500 500 500 500 0 0 0 0 4 8 12 16 20 24 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 16 0 10 20 30 40 50 60 Work load [kg] Work load
Connection thread 17 15.2 1 4 KGU08-02 18.5 8 15.2 3 8 KGU08-03
Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St.
Manifold block assembly number differs according to an attached lead wire assembly based on the connector specification (Single, Double). Select an appropriate part number from among the manifold block assembly numbers shown below.
Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St.
Can hold an intermediate cylinder position for an extended time. When combined with a double check spacer with built-in double check valve, it is unaffected by air leakage between the spool valves, making it possible to hold a cylinder at an intermediate stopping position for an extended time.