(Effective energizing time is over 62 ms at 24 VDC.)
Overcurrent error Residual pressure error Applied pressure error Auto-shift error System error Available response time settings PSE200 PSE300 20 ms, 160 ms, 640 ms Load current of switch output (OUT2) exceeds 80 mA. 20 ms, 160 ms, 640 ms, 1280 ms
10 5 2.86 20 10 5 Parameter *1,*2 Para.
Label (Display item), Set value (Threshold value) Sub screen Set value (Threshold value) Hysteresis value Visualization of Settings Peak value Bottom value Delay time Delay Time 1.5 ms *1 or less 25 mA *2 or less Current Consumption *1 Select from 1.5 ms or less, 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, or 5000 ms. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) The
Port size M5 x 0.8 t 10.5 15 18 20 t 10.5 15 18 20 Series Assembly part no.
10 ms increments (0 to 30 sec.)
for the distances to the moment center An [mm] Positioning time Tp [ms] Positioning repeatability [m] L3 Fig.2 Fig.1 L2 + A2 Fig.1 Table 1 Select an actuator temporarily. 2 A1+ L1 From Table 2, temporarily select the LAT3-20, which satisfies the positioning repeatability 100 m and the minimum stroke that satisfies the stroke St = 15 Table 2 Select a model temporarily based on the required
SY5000222-1A [for 10 valves (20 pcs.)] SY7000221-1A [for 10 valves (30 pcs.)] SY3000222-1A [for 10 valves (20 pcs.)] SY5000221-1A [for 10 valves (20 pcs.)] SY300023-24A [for 10 valves (20 pcs.)]
Caution When using an exhaust cleaner, mount it downwards.
New New Compact Vacuum Unit Ejector/Vacuum Pump System RoHS Air consumption: 17% reduced 17% 17% 17% 21% 21% 21% Response time of the valve: 21% increased 5 m ms 5 ms Quick response Energysaving Vacuum pressure reached: 25% 28 ms ms Vacuum response time: 28 ms Compared with existing model (Shortened by 25%; Comparison with other SMC products) 0.88 14.5 Air consumption SCFM (L/min (ANR))
Example) Assume circuit C with an operating pressure of 0.5 MPa, load weight of 10 kg, fluctuation to 20 kg and a cylinder bore of 32 mm.
) 20 10 20 10 Min. speed [mm/s] (Speed tuning control) 25 13 27 14 -109No.
It takes 10[ms] to switch the channel.
For LECSB, set [ms/div] and [Number of collection Div] to the horizontal axis (time axis). [ms/div] [Number of collection Div] will be [Measurement time]. Click of [ms/div] and set the DiV number. The unit ms of [Number of collection Div] is 1000ms1s.
When designing an application, be sure to allow sufficient space for maintenance and inspection. In cases of high piston speed, the use of an auto switch (DF5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
When designing an application, be sure to allow sufficient space for maintenance and inspection. In cases of high piston speed, the use of an auto switch (DF5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
VQC 20 16 8 20 20 08 Note) Two manifold stations are required for double solenoid 3 position valves (dual body type).
Port exhaust 2 Supply valve maintains vacuum by energization (20 ms or more). Stopping the vacuum turns on the release valve.
Abnormality detection The controller generates an alarm or an error when an abnormality is detected. Details of the alarm or error can be checked using a PC (using the controller setting software). Refer to the manuals of the Controller Setting Software (No. JXC*-OMU0023) for details of the alarms and errors.